別表第七(第八十五条、第八十六条関係)
Appended Table 7
| Type of Machinery or Other Such Equipment | Matters | Drawings, etc. |
| (i) power presses (limited to mechanical presses with an eccentric mechanism such as a crankshaft, and hydraulic presses) | (i) type (ii) pressure capability (iii) length of stroke (iv) stopping performance (v) type of changeover switch (vi) for a mechanical press with an eccentric mechanism such as a crankshaft: (a) model of the clutch (b) model of the brake (c) number of strokes per minute (d) die height (e) amount of slide adjustment (f) setting position of the overrun monitoring device (g) number of clutch engagement points (vii) for a hydraulic press: (a) maximum descending speed of the slide (b) inertial descending value (viii) outline of use: (a) use (b) stroke (c) processing (ix) outline of safety measures (x) for one with a mechanism for preventing danger due to the slide, its performance | (i) structural drawing or catalog of the power press (ii) for a power press that has passed the type examination, a copy of the sticker certifying passage of the type examination (iii) for a power press to which a safety device is to be attached, a copy of the sticker certifying passage of the type examination pertaining to that safety device, and a structural drawing or catalog of that safety device (iv) for a power press other than those listed in the preceding two items, a drawing or catalog showing the outline of safety measures |
| (ii) melting furnaces for metals and other minerals (limited to those with a capacity of 1 ton or more) | (i) type, model, name of manufacturer, and year and month of manufacture (ii) type and properties of the metals and other minerals handled (iii) method of heating (iv) standard amount of charge, temperature, pressure, and other use conditions (v) structure, material, and main dimensions (vi) structure, material, and main dimensions of the cooling equipment, oxygen blowing equipment, pits, and other main attached facilities | (i) structural drawing of the melting furnace and its main attached facilities (ii) drawing showing the outline of the surrounding area of the installation place |
| (iii) chemical facilities (excluding piping) (excluding those for which the amount of dangerous goods manufactured or handled, or of substances with a flash point of 65°C or higher manufactured or handled, is below the standards specified by the Minister of Health, Labour and Welfare) | (i) type, model, and functions (ii) names and properties of the dangerous goods manufactured or handled, or of the substances with a flash point of 65°C or higher manufactured or handled (iii) standard amount of charge, temperature, pressure, and other use conditions (iv) structure, material, and main dimensions (v) structure, material, and main dimensions of the main attached facilities and piping | Arrangement plan and structural drawings of the chemical facilities, the main attached facilities, and piping |
| (iv) drying equipment (limited to the drying equipment set forth in Article 6, item (viii), (a) or (b) of the Order) | (i) type, model, capability, name of manufacturer, and year and month of manufacture (ii) type and properties of the substances to be dried (iii) method of heating (iv) temperature, pressure, and other use conditions (v) structure, material, and main dimensions (vi) functions, structure, material, and main dimensions of the ventilation system, temperature measuring apparatus, temperature adjusting apparatus, and other main attached facilities | (i) structural drawing (ii) drawing showing the outline of the surrounding area of the installation place |
| (v) acetylene welding equipment (excluding mobile types) | (i) structure, material, and main dimensions of the floor area, walls, roof, ceiling, entrance and exit doors, and exhaust pipe of the generator room, and the number of devices housed (ii) type, model, name of manufacturer, and year and month of manufacture of the generator (iii) type, model, name of manufacturer, year and month of manufacture, number, structure, material, and main dimensions of the safety equipment (iv) name, structure, material, and main dimensions of the purifier and other attached appliances (v) structure and capacity of the sludge pit of carbide | (i) arrangement plan (ii) structural drawings of the generator and safety equipment (iii) structural drawing of the generator room (iv) drawing showing the outline of the surrounding area of the installation place |
| (vi) gas welding equipment using manifolds (excluding mobile types) | (i) structure and main dimensions of the gas manifold room, and name of the gas stored and the maximum gas storage amount (ii) structure and main dimensions of the gas manifolds (iii) type, model, name of manufacturer, year and month of manufacture, number, structure, material, and main dimensions of the safety equipment (iv) name, structure, material, and main dimensions of the piping, valves, and other attached appliances | (i) arrangement plan (ii) structural drawing of the safety equipment (iii) structural drawing of the gas manifold room (iv) drawing showing the outline of the surrounding area of the installation place |
| (vii) skyline logging cable cranes (limited to those whose prime mover has a rated power output exceeding 7.5 kW) | (i) rope reeving system (ii) maximum working load (iii) slope distance, inclined angle, and central dangling ratio of effective spans (iv) structure and diameters of the main cable and work ropes (v) safety coefficient of the main cable and work ropes (a strength calculation document is to be attached) (vi) type, rated power output, and maximum traction force of the yarder (vii) period of installation | Arrangement plan |
| (viii) timber cableways (limited to those with a total slope distance of effective spans of 350 m or more) | (i) type (ii) maximum working load and clearance between carriers (iii) total slope distance of effective spans (iv) slope distance, inclined angle, and central dangling ratio of the longest effective span (v) structure and diameters of the main cable and towing rope (vi) safety coefficient of the main cable and towing rope (a strength calculation document is to be attached) (vii) for those that are power driven, type and rated power output of the timber hauling machine (viii) period of installation | Arrangement plan |
| (ix) railway equipment | (i) purpose of use (ii) positions of the starting point and ending point, and the difference in altitude between them (average gradient) (iii) length of the track (iv) minimum radius of curvature and steepest gradient (v) gauge of the track, distinction between single and double track, and weight of the rails (vi) length, width, and structure of bridges or landing piers (vii) type, number, model, weight, traction force, and main dimensions of power cars (viii) model, capability, and main dimensions of the winch (ix) type and function of the brakes (x) conditions of signaling, warning, and lighting equipment (xi) maximum operating speed (xii) installation place and structure of the device for preventing breaking into a run (xiii) for those installed underground, relationship between the railway equipment and its surroundings | If the matters listed in the middle column cannot be clearly indicated in writing, drawings such as a plan view, cross-sectional view, and structural drawing pertaining to those matters |
| (x) concrete form shoring (limited to those with support posts of a height of 3.5 m or more) | (i) outline of the concrete structure to be placed (ii) structure, material, and main dimensions (iii) period of installation | Assembly drawing and arrangement plan |
| (xi) temporary passages (limited to those whose height and length are each 10 m or more) | (i) installation place (ii) structure, material, and main dimensions (iii) period of installation | Plan view, side view, and cross-sectional view |
| (xii) scaffoldings (limited to those with a structure of a height of 10 m or more for scaffoldings other than hanging scaffoldings and cantilever scaffoldings) | (i) installation place (ii) type and purpose of use (iii) structure, material, and main dimensions | Assembly drawing and arrangement plan |
| (xiii) facilities to keep airtight the emission sources of organic solvent vapor, local exhaust ventilation, push-pull type ventilation systems, or general ventilation systems set forth in Article 5 or Article 6 of the Organic Solvent Ordinance (including the case where these provisions apply mutatis mutandis pursuant to Article 38-8 of the Specified Chemical Substances Ordinance) (excluding mobile types) | (i) outline of the organic solvent work (meaning the organic solvent work listed in Article 1, paragraph (1), item (vi) of the Organic Solvent Ordinance; hereinafter the same applies in this item) (ii) outline of the machines or facilities that are emission sources of organic solvent vapor (meaning the organic solvents listed in Appended Table 6-2 of the Order; hereinafter the same applies in this item) (iii) method of controlling emissions of organic solvent vapor (iv) for facilities to keep the emission source of organic solvent vapor airtight, the method of keeping it airtight and an outline of the structure of the main parts of the facilities (v) for a general ventilation system, the model, an outline of the structure of the main parts of the system, and its function | (i) drawing of facilities, etc. (ii) drawing of the workplace where organic solvent work is carried out (iii) for local exhaust ventilation, a local exhaust ventilation specification document (Form No. 25) (iv) for a push-pull type ventilation system, a push-pull type ventilation system specification document (Form No. 26) |
| (xiv) facilities to keep airtight the emission sources of dust of lead, etc. or sintered ore, etc., local exhaust ventilation, or push-pull type ventilation systems prescribed in Article 2, Articles 5 through 15, and Articles 17 through 20 of the Lead Poisoning Ordinance | (i) outline of the lead work (meaning the lead work listed in Article 1, item (v) of the Lead Poisoning Ordinance; hereinafter the same applies in this item) (ii) outline of the machines or facilities that are emission sources of dust of lead, etc. (meaning the lead, etc. listed in Article 1, item (i) of the Lead Poisoning Ordinance; hereinafter the same applies in this item) or sintered ore, etc. (meaning the sintered ore, etc. listed in item (ii) of the same Article; hereinafter the same applies in this item) (iii) method of controlling emissions of dust of lead, etc. or sintered ore, etc. (iv) for facilities to keep the emission source of dust of lead, etc. or sintered ore, etc. airtight, the method of keeping it airtight and an outline of the structure of the main structural parts of the facilities | (i) drawing of facilities, etc. (ii) drawing of the workplace where lead work is carried out (iii) for local exhaust ventilation, a local exhaust ventilation specification document (Form No. 25) (iv) for a push-pull type ventilation system, a push-pull type ventilation system specification document (Form No. 26) |
| (xv) machines or equipment used for the work listed in Appended Table 5, item (ii) of the Order (hereinafter referred to as "work" in this item) | (i) outline of the work (ii) outline of the machines or facilities that are emission sources of tetraalkyl lead vapor (meaning the tetraalkyl lead set forth in Appended Table 5, item (i) of the Order; hereinafter the same applies in this item) (iii) amount of gasoline mixed with tetraalkyl lead that is handled (iv) model of the machines or equipment used in the work, and an outline of the structure of their main parts and their functions (v) provision of protective equipment, disinfectants, etc. (vi) outline of body washing facilities | (i) drawing of the machines or equipment used in the work (ii) drawing of the workplace where the work is carried out |
| (xvi) facilities to manufacture class 1 substances listed in Article 2, paragraph (1), item (i) of the Specified Chemical Substances Ordinance (hereinafter referred to as "class 1 substances" in this item) or specified class 2 substances, etc. under Article 4, paragraph (1) of the Specified Chemical Substances Ordinance (hereinafter referred to as "specified class 2 substances, etc." in this item) | (i) outline of the work of manufacturing class 1 substances or specified class 2 substances, etc. (ii) outline of the structure of the main structural parts (iii) method of keeping airtight and an outline of the measures to prevent health impairment when having workers handle those substances | (i) drawing showing the surrounding situation and the relationship with the surrounding areas (ii) structure of the building where the facilities that manufacture class 1 substances or specified class 2 substances, etc. are installed (iii) drawing showing the layout of the facilities that manufacture class 1 substances or specified class 2 substances, etc. (iv) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25) (v) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26) |
| (xvii) specified chemical facilities set forth in Article 15, paragraph (1), item (x) of the Order (hereinafter referred to as "specified chemical facilities" in this item) and their attached facilities | (i) outline of the work of manufacturing or handling specified class 2 substances (meaning the specified class 2 substances listed in Article 2, paragraph (1), item (iii) of the Specified Chemical Substances Ordinance; hereinafter the same applies in this item and the following item) or class 3 substances (meaning the substances listed in Appended Table 3, item (iii) of the Order) (ii) outline of the structure of the main structural parts (iii) outline of the structure of the attached facilities | (i) drawing showing the surrounding situation and the relationship with the surrounding areas (ii) structure of the building where the specified chemical facilities are installed (iii) drawing showing the layout of the specified chemical facilities and their attached facilities (iv) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25) (v) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26) |
| (xviii) emission control facilities installed in an indoor workplace where gas, vapor, or dust of specified class 2 substances or controlled class 2 substances listed in Article 2, paragraph (1), item (v) of the Specified Chemical Substances Ordinance (hereinafter referred to as "controlled class 2 substances" in this item) is released (excluding those pertaining solely to the work listed in Article 2-2, item (ii) or items (iv) through (viii) of the Specified Chemical Substances Ordinance) | (i) outline of the work of manufacturing or handling specified class 2 substances or controlled class 2 substances (ii) for facilities to keep the emission source of gas, vapor, or dust of specified class 2 substances or controlled class 2 substances airtight, the method of keeping it airtight, an outline of the structure of the main structural parts, and their functions (iii) for a general ventilation system, the model, an outline of the structure of the main structural parts, and its function | (i) drawing showing the surrounding situation and the relationship with the surrounding areas (ii) drawing showing the whole workplace (iii) drawing of the facilities to keep the emission source of gas, vapor, or dust of specified class 2 substances or controlled class 2 substances airtight, or of the general ventilation system (iv) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25) (v) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26) |
| (xix) exhaust gas treatment devices set forth in Article 10, paragraph (1) of the Specified Chemical Substances Ordinance that pertain to acrolein | (i) outline of the work of manufacturing or handling acrolein (ii) treatment method and treatment capability for exhaust gas (iii) outline of the structure of the main structural parts | (i) drawing showing the surrounding situation and the relationship with the surrounding areas (ii) drawing of the structure of the exhaust gas treatment devices (iii) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25) (iv) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26) |
| (xx) waste liquid treatment devices set forth in Article 11, paragraph (1) of the Specified Chemical Substances Ordinance | (i) outline of the work of waste liquid treatment (ii) treatment method and treatment capability for waste liquid (iii) outline of the structure of the main structural parts | (i) drawing showing the surrounding situation and the relationship with the surrounding areas (ii) drawing of the structure of the waste liquid treatment devices (iii) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25) (iv) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26) |
| (xx)-2 emission control facilities pertaining to the 1,3-butadiene, etc. set forth in Article 38-17, paragraph (1) of the Specified Chemical Substances Ordinance (hereinafter referred to as "1,3-butadiene, etc." in this item) (excluding those installed outdoors) | (i) outline of the work of taking samples from facilities that manufacture or handle 1,3-butadiene, etc., or of carrying out maintenance and inspection of those facilities (ii) for facilities to keep the emission source of gas of 1,3-butadiene, etc. airtight, the method of keeping it airtight, an outline of the structure of the main structural parts, and their functions (iii) for a general ventilation system, the model, an outline of the structure of the main structural parts, and its function | (i) drawing showing the surrounding situation and the relationship with the surrounding areas (ii) drawing showing the whole workplace (iii) drawing of the facilities to keep the emission source of gas of 1,3-butadiene, etc. airtight, or of the general ventilation system (iv) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25) (v) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26) |
| (xx)-3 emission control facilities pertaining to the diethyl sulfate, etc. set forth in Article 38-18, paragraph (1) of the Specified Chemical Substances Ordinance (hereinafter referred to as "diethyl sulfate, etc." in this item) (excluding those installed outdoors) | (i) outline of the work of handling diethyl sulfate, etc. as a catalyst (ii) for facilities to keep the emission source of vapor of diethyl sulfate, etc. airtight, the method of keeping it airtight, an outline of the structure of the main structural parts, and their functions (iii) for a general ventilation system, the model, an outline of the structure of the main structural parts, and its function | (i) drawing showing the surrounding situation and the relationship with the surrounding areas (ii) drawing showing the whole workplace (iii) drawing of the facilities to keep the emission source of vapor of diethyl sulfate, etc. airtight, or of the general ventilation system (iv) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25) (v) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26) |
| (xx)-4 facilities that manufacture or handle the 1,3-propane sultone, etc. set forth in Article 38-19 of the Specified Chemical Substances Ordinance (hereinafter referred to as "1,3-propane sultone, etc." in this item) and their attached facilities | (i) outline of the work of manufacturing or handling 1,3-propane sultone, etc. (ii) outline of the structure of the main structural parts (iii) outline of the structure of the attached facilities (iv) method of keeping airtight and an outline of the measures to prevent health impairment when having workers handle that substance | (i) drawing showing the surrounding situation and the relationship with the surrounding areas (ii) structure of the building where the facilities that manufacture or handle 1,3-propane sultone, etc. are installed (iii) drawing showing the layout of the facilities that manufacture or handle 1,3-propane sultone, etc. and their attached facilities (iv) drawing of the facilities that manufacture or handle 1,3-propane sultone, etc. and their attached facilities |
| (xxi) radiation apparatus set forth in Article 15, paragraph (1) of the Ionizing Radiation Ordinance (excluding certified apparatus with indication set forth in Article 12-5, paragraph (2) of the Act on the Regulation of Radioisotopes, etc. (Act No. 167 of 1957) or specified certified apparatus with indication set forth in paragraph (3) of the same Article; hereinafter the same applies in this item) | Outline of the work using radiation apparatus, and of products and work processes | (i) drawing showing the controlled area (ii) radiation apparatus specification document (Form No. 27) |
| (xxii) air conditioning facilities or mechanical ventilation facilities of the centralized management type set forth in Article 5 of the Ordinance on Health Standards in the Office (Order of the Ministry of Labour No. 43 of 1972) | (i) air treatment method (a) air purification method (b) dehumidifying and moisture-adding method (c) humidifying method (d) cooling method (ii) ventilation capability (iii) type and capability of the blower or exhauster (iv) structure of the main structural parts (v) system for supplying or exhausting air (vi) procedure for facility inspection | If the matters listed in the middle column cannot be clearly indicated in writing, drawings such as a structural drawing and piping arrangement plan pertaining to those matters |
| (xxiii) machines or facilities having the specified dust emission sources listed in Appended Table 2, items (vi) and (viii) of the Dust Ordinance, and the mold breaking equipment listed in item (xiv) of the same Table | (i) outline of the dusty task (meaning the dusty task under Article 2, paragraph (1), item (i) of the Dust Ordinance; hereinafter the same applies) (ii) type, name, capability, and number of machines or facilities, and the method of preventing dispersal of dust (iii) when facilities to keep the emission source of dust airtight are used as the method of preventing dispersal of dust, the method of keeping it airtight, an outline of the structure of the main structural parts, and their functions (iv) when a method other than the method under the preceding item and the method of preventing dispersal of dust by local exhaust ventilation is used, the model of the facilities for preventing dispersal of dust, an outline of the structure of the main structural parts, and their capability | (i) drawing showing the surrounding situation and the relationship with the surrounding areas (ii) drawing showing the layout of the main machines or facilities in the workplace (iii) drawing showing the structure of the facilities for preventing dispersal of dust other than local exhaust ventilation |
| (xxiv) local exhaust ventilation or push-pull type ventilation systems installed pursuant to the provisions of Article 4 or the proviso to Article 27, paragraph (1) of the Dust Ordinance | Outline of the dusty task | (i) drawing showing the surrounding situation and the relationship with the surrounding areas (ii) drawing showing the layout of the main machines or facilities in the workplace (iii) for local exhaust ventilation, a local exhaust ventilation specification document (Form No. 25) (iv) for a push-pull type ventilation system, a push-pull type ventilation system specification document (Form No. 26) |
| (xxv) emission control facilities installed in an indoor workplace where dust of asbestos, etc. is released | (i) outline of the work of handling asbestos, etc. or manufacturing it for testing or research, or of manufacturing samples for asbestos analysis, etc. (meaning the samples for asbestos analysis, etc. prescribed in Article 6, item (xxiii) of the Order) (ii) for facilities to keep the emission source of dust of asbestos, etc. airtight, the method of keeping it airtight, an outline of the structure of the main structural parts, and their functions (iii) for a general ventilation system, the model, an outline of the structure of the main structural parts, and its function | (i) drawing showing the surrounding situation and the relationship with the surrounding areas (ii) drawing showing the whole workplace (iii) drawing of the facilities to keep the emission source of dust of asbestos, etc. airtight, or of the general ventilation system (iv) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25) (v) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26) |
| 機械等の種類 | 事項 | 図面等 |
| 一 動力プレス(機械プレスでクランク軸等の偏心機構を有するもの及び液圧プレスに限る。) | 一 種類 二 圧力能力 三 ストローク長さ 四 停止性能 五 切替えスイツチの種類 六 機械プレスでクランク軸等の偏心機構を有するものにあつては、 イ クラツチの型式 ロ ブレーキの型式 ハ 毎分ストローク数 ニ ダイハイト ホ スライド調節量 ヘ オーバーラン監視装置の設定位置 ト クラツチの掛合い箇所の数 七 液圧プレスにあつては、 イ スライドの最大下降速度 ロ 慣性下降値 八 使用の概要 イ 用途 ロ 行程 ハ 加工 九 安全措置の概要 十 スライドによる危険を防止するための機構を有するものにあつては、その性能 | 一 動力プレスの構造図又はカタログ 二 型式検定に合格した動力プレスにあつては、型式検定合格標章の写し 三 安全装置を取り付ける動力プレスにあつては、当該安全装置に係る型式検定合格標章の写し及び当該安全装置の構造図又はカタログ 四 前二号に掲げる動力プレス以外の動力プレスにあつては、安全措置の概要を示す図面又はカタログ |
| 二 金属その他の鉱物の溶解炉(容量が一トン以上のものに限る。) | 一 種類、型式、製造者及び製造年月 二 取り扱う金属その他の鉱物の種類及び性状 三 加熱の方法 四 標準仕込量、温度、圧力その他の使用条件 五 構造、材質及び主要寸法 六 冷却装置、酸素吹込装置、ピツトその他の主要な附属設備の構造、材質及び主要寸法 | 一 当該溶解炉及び主要な附属設備の構造図 二 設置場所の四隣の概要を示す図面 |
| 三 化学設備(配管を除く。)(製造し、若しくは取り扱う危険物又は製造し、若しくは取り扱う引火点が六十五度以上の物の量が厚生労働大臣が定める基準に満たないものを除く。) | 一 種類、型式及び機能 二 製造し、若しくは取り扱う危険物又は製造し、若しくは取り扱う引火点が六十五度以上の物の名称及び性状 三 標準仕込量、温度、圧力その他の使用条件 四 構造、材質及び主要寸法 五 主要な附属設備及び配管の構造、材質及び主要寸法 | 当該化学設備、主要な附属設備及び配管の配置図及び構造図 |
| 四 乾燥設備(令第六条第八号イ又はロの乾燥設備に限る。) | 一 種類、型式、能力、製造者及び製造年月 二 乾燥物の種類及び性状 三 加熱の方法 四 温度、圧力その他の使用条件 五 構造、材質及び主要寸法 六 換気装置、温度測定装置、温度調整装置その他の主要な附属設備の機能、構造、材質及び主要寸法 | 一 構造図 二 設置場所の四隣の概要を示す図面 |
| 五 アセチレン溶接装置(移動式のものを除く。) | 一 発生器室の床面積、壁、屋根、天井、出入口の戸及び排気筒の構造、材質及び主要寸法並びに収容する装置の数 二 発生器の種類、型式、製造者及び製造年月 三 安全器の種類、型式、製造者、製造年月及び個数並びに構造、材質及び主要寸法 四 清浄器その他の附属器具の名称、構造、材質及び主要寸法 五 カーバイドのかすだめの構造及び容積 | 一 配置図 二 発生器及び安全器の構造図 三 発生器室の構造図 四 設置場所の四隣の概要を示す図面 |
| 六 ガス集合溶接装置(移動式のものを除く。) | 一 ガス装置室の構造及び主要寸法並びに貯蔵するガスの名称及び最大ガス貯蔵量 二 ガス集合装置の構造及び主要寸法 三 安全器の種類、型式、製造者、製造年月及び個数並びに構造、材質及び主要寸法 四 配管、バルブその他の附属器具の名称、構造、材質及び主要寸法 | 一 配置図 二 安全器の構造図 三 ガス装置室の構造図 四 設置場所の四隣の概要を示す図面 |
| 七 機械集材装置(原動機の定格出力が七・五キロワツトを超えるものに限る。) | 一 索張り方式 二 最大使用荷重 三 支間の斜距離、傾斜角及び中央垂下比 四 主索及び作業索の構造及び直径 五 主索及び作業索の安全係数(強度計算書を添付すること。) 六 集材機の型式、定格出力及び最大けん引力 七 設置期間 | 配置図 |
| 八 運材索道(支間の斜距離の合計が三百五十メートル以上のものに限る。) | 一 種類 二 最大使用荷重及び搬器と搬器との間隔 三 支間の斜距離の合計 四 最長の支間の斜距離、傾斜角及び中央垂下比 五 主索及びえい索の構造及び直径 六 主索及びえい索の安全係数(強度計算書を添付すること。) 七 動力式のものにあつては、運材機の型式及び定格出力 八 設置期間 | 配置図 |
| 九 軌道装置 | 一 使用目的 二 起点及び終点の位置並びにその高低差(平均勾配) 三 軌道の長さ 四 最小曲線半径及び最急勾配 五 軌間、単線又は複線の区別及び軌条の重量 六 橋梁又は桟橋の長さ、幅及び構造 七 動力車の種類、数、形式、自重、けん引力及び主要寸法 八 巻上げ機の形式、能力及び主要寸法 九 ブレーキの種類及び作用 十 信号、警報及び照明設備の状況 十一 最大運転速度 十二 逸走防止装置の設置箇所及び構造 十三 地下に設置するものにあつては、軌道装置と周囲との関係 | 中欄に掲げる事項が書面により明示できないときは、当該事項に係る平面図、断面図、構造図等の図面 |
| 十 型枠支保工(支柱の高さが三・五メートル以上のものに限る。) | 一 打設しようとするコンクリート構造物の概要 二 構造、材質及び主要寸法 三 設置期間 | 組立図及び配置図 |
| 十一 架設通路(高さ及び長さがそれぞれ十メートル以上のものに限る。) | 一 設置箇所 二 構造、材質及び主要寸法 三 設置期間 | 平面図、側面図及び断面図 |
| 十二 足場(つり足場、張出し足場以外の足場にあつては、高さが十メートル以上の構造のものに限る。) | 一 設置箇所 二 種類及び用途 三 構造、材質及び主要寸法 | 組立図及び配置図 |
| 十三 有機則第五条又は第六条(特化則第三十八条の八においてこれらの規定を準用する場合を含む。)の有機溶剤の蒸気の発散源を密閉する設備、局所排気装置、プッシュプル型換気装置又は全体換気装置(移動式のものを除く。) | 一 有機溶剤業務(有機則第一条第一項第六号に掲げる有機溶剤業務をいう。以下この項において同じ。)の概要 二 有機溶剤(令別表第六の二に掲げる有機溶剤をいう。以下この項において同じ。)の蒸気の発散源となる機械又は設備の概要 三 有機溶剤の蒸気の発散の抑制の方法 四 有機溶剤の蒸気の発散源を密閉する設備にあつては、密閉の方式及び当該設備の主要部分の構造の概要 五 全体換気装置にあつては、型式、当該装置の主要部分の構造の概要及びその機能 | 一 設備等の図面 二 有機溶剤業務を行う作業場所の図面 三 局所排気装置にあつては局所排気装置摘要書(様式第二十五号) 四 プッシュプル型換気装置にあつてはプッシュプル型換気装置摘要書(様式第二十六号) |
| 十四 鉛則第二条、第五条から第十五条まで及び第十七条から第二十条までに規定する鉛等又は焼結鉱等の粉じんの発散源を密閉する設備、局所排気装置又はプッシュプル型換気装置 | 一 鉛業務(鉛則第一条第五号に掲げる鉛業務をいう。以下この項において同じ。)の概要 二 鉛等(鉛則第一条第一号に掲げる鉛等をいう。以下この項において同じ。)又は焼結鉱等(同条第二号に掲げる焼結鉱等をいう。以下この項において同じ。)の粉じんの発散源となる機械又は設備の概要 三 鉛等又は焼結鉱等の粉じんの発散の抑制の方法 四 鉛等又は焼結鉱等の粉じんの発散源を密閉する設備にあつては、密閉の方法及び当該設備の主要構造部分の構造の概要 | 一 設備等の図面 二 鉛業務を行う作業場所の図面 三 局所排気装置にあつては局所排気装置摘要書(様式第二十五号) 四 プッシュプル型換気装置にあつてはプッシュプル型換気装置摘要書(様式第二十六号) |
| 十五 令別表第五第二号に掲げる業務(以下この項において「業務」という。)に用いる機械又は装置 | 一 業務の概要 二 四アルキル鉛(令別表第五第一号の四アルキル鉛をいう。以下この項において同じ。)の蒸気の発散源となる機械又は設備の概要 三 四アルキル鉛を混入するガソリンの取扱量 四 業務に用いる機械又は装置の型式並びにその主要部分の構造の概要及び機能 五 保護具、消毒薬等の備付け状況 六 洗身設備の概要 | 一 業務に用いる機械又は装置の図面 二 業務を行う作業場所の図面 |
| 十六 特化則第二条第一項第一号に掲げる第一類物質(以下この項において「第一類物質」という。)又は特化則第四条第一項の特定第二類物質等(以下この項において「特定第二類物質等」という。)を製造する設備 | 一 第一類物質又は特定第二類物質等を製造する業務の概要 二 主要構造部分の構造の概要 三 密閉の方式及び労働者に当該物質を取り扱わせるときは健康障害防止の措置の概要 | 一 周囲の状況及び四隣との関係を示す図面 二 第一類物質又は特定第二類物質等を製造する設備を設置する建築物の構造 三 第一類物質又は特定第二類物質等を製造する設備の配置の状況を示す図面 四 局所排気装置が設置されている場合にあつては、局所排気装置摘要書(様式第二十五号) 五 プッシュプル型換気装置が設置されている場合にあつてはプッシュプル型換気装置摘要書(様式第二十六号) |
| 十七 令第十五条第一項第十号の特定化学設備(以下この項において「特定化学設備」という。)及びその附属設備 | 一 特定第二類物質(特化則第二条第一項第三号に掲げる特定第二類物質をいう。以下この項及び次項において同じ。)又は第三類物質(令別表第三第三号に掲げる物をいう。)を製造し、又は取り扱う業務の概要 二 主要構造部分の構造の概要 三 附属設備の構造の概要 | 一 周囲の状況及び四隣との関係を示す図面 二 特定化学設備を設置する建築物の構造 三 特定化学設備及びその附属設備の配置状況を示す図面 四 局所排気装置が設置されている場合にあつては、局所排気装置摘要書(様式第二十五号) 五 プッシュプル型換気装置が設置されている場合にあつてはプッシュプル型換気装置摘要書(様式第二十六号) |
| 十八 特定第二類物質又は特化則第二条第一項第五号に掲げる管理第二類物質(以下この項において「管理第二類物質」という。)のガス、蒸気又は粉じんが発散する屋内作業場に設ける発散抑制の設備(特化則第二条の二第二号又は第四号から第八号までに掲げる業務のみに係るものを除く。) | 一 特定第二類物質又は管理第二類物質を製造し、又は取り扱う業務の概要 二 特定第二類物質又は管理第二類物質のガス、蒸気又は粉じんの発散源を密閉する設備にあつては、密閉の方式、主要構造部分の構造の概要及びその機能 三 全体換気装置にあつては、型式、主要構造部分の構造の概要及びその機能 | 一 周囲の状況及び四隣との関係を示す図面 二 作業場所の全体を示す図面 三 特定第二類物質又は管理第二類物質のガス、蒸気又は粉じんの発散源を密閉する設備又は全体換気装置の図面 四 局所排気装置が設置されている場合にあつては、局所排気装置摘要書(様式第二十五号) 五 プッシュプル型換気装置が設置されている場合にあつてはプッシュプル型換気装置摘要書(様式第二十六号) |
| 十九 特化則第十条第一項の排ガス処理装置であつて、アクロレインに係るもの | 一 アクロレインを製造し、又は取り扱う業務の概要 二 排気の処理方式及び処理能力 三 主要構造部分の構造の概要 | 一 周囲の状況及び四隣との関係を示す図面 二 排ガス処理装置の構造の図面 三 局所排気装置が設置されている場合にあつては、局所排気装置摘要書(様式第二十五号) 四 プッシュプル型換気装置が設置されている場合にあつてはプッシュプル型換気装置摘要書(様式第二十六号) |
| 二十 特化則第十一条第一項の排液処理装置 | 一 排液処理の業務の概要 二 排液の処理方式及び処理能力 三 主要構造部分の構造の概要 | 一 周囲の状況及び四隣との関係を示す図面 二 排液処理装置の構造の図面 三 局所排気装置が設置されている場合にあつては、局所排気装置摘要書(様式第二十五号) 四 プッシュプル型換気装置が設置されている場合にあつてはプッシュプル型換気装置摘要書(様式第二十六号) |
| 二十の二 特化則第三十八条の十七第一項の一・三―ブタジエン等(以下この項において「一・三―ブタジエン等」という。)に係る発散抑制の設備(屋外に設置されるものを除く。) | 一 一・三―ブタジエン等を製造し、若しくは取り扱う設備から試料を採取し、又は当該設備の保守点検を行う作業の概要 二 一・三―ブタジエン等のガスの発散源を密閉する設備にあつては、密閉の方式、主要構造部分の構造の概要及びその機能 三 全体換気装置にあつては、型式、主要構造部分の構造の概要及びその機能 | 一 周囲の状況及び四隣との関係を示す図面 二 作業場所の全体を示す図面 三 一・三―ブタジエン等のガスの発散源を密閉する設備又は全体換気装置の図面 四 局所排気装置が設置されている場合にあつては、局所排気装置摘要書(様式第二十五号) 五 プッシュプル型換気装置が設置されている場合にあつてはプッシュプル型換気装置摘要書(様式第二十六号) |
| 二十の三 特化則第三十八条の十八第一項の硫酸ジエチル等(以下この項において「硫酸ジエチル等」という。)に係る発散抑制の設備(屋外に設置されるものを除く。) | 一 硫酸ジエチル等を触媒として取り扱う作業の概要 二 硫酸ジエチル等の蒸気の発散源を密閉する設備にあつては、密閉の方式、主要構造部分の構造の概要及びその機能 三 全体換気装置にあつては、型式、主要構造部分の構造の概要及びその機能 | 一 周囲の状況及び四隣との関係を示す図面 二 作業場所の全体を示す図面 三 硫酸ジエチル等の蒸気の発散源を密閉する設備又は全体換気装置の図面 四 局所排気装置が設置されている場合にあつては、局所排気装置摘要書(様式第二十五号) 五 プッシュプル型換気装置が設置されている場合にあつてはプッシュプル型換気装置摘要書(様式第二十六号) |
| 二十の四 特化則第三十八条の十九の一・三―プロパンスルトン等(以下この項において「一・三―プロパンスルトン等」という。)を製造し、又は取り扱う設備及びその附属設備 | 一 一・三―プロパンスルトン等を製造し、又は取り扱う業務の概要 二 主要構造部分の構造の概要 三 附属設備の構造の概要 四 密閉の方式及び労働者に当該物質を取り扱わせるときは健康障害防止の措置の概要 | 一 周囲の状況及び四隣との関係を示す図面 二 一・三―プロパンスルトン等を製造し、又は取り扱う設備を設置する建築物の構造 三 一・三―プロパンスルトン等を製造し、又は取り扱う設備及びその附属設備の配置状況を示す図面 四 一・三―プロパンスルトン等を製造し、又は取り扱う設備及びその附属設備の図面 |
| 二十一 電離則第十五条第一項の放射線装置(放射性同位元素等の規制に関する法律(昭和三十二年法律第百六十七号)第十二条の五第二項に規定する表示付認証機器又は同条第三項に規定する表示付特定認証機器を除く。以下この項において同じ。) | 放射線装置を用いる業務、製品及び作業工程の概要 | 一 管理区域を示す図面 二 放射線装置摘要書(様式第二十七号) |
| 二十二 事務所衛生基準規則(昭和四十七年労働省令第四十三号)第五条の空気調和設備又は機械換気設備で中央管理方式のもの | 一 空気の処理方法 イ 空気の浄化方法 ロ 減湿・与湿方法 ハ 加湿方法 ニ 冷却方法 二 換気能力 三 送風機又は排風機の種類及び能力 四 主要構造部分の構造 五 空気の供給又は排気の系統 六 設備点検の要領 | 中欄に掲げる事項が書面により明示できないときは、当該事項に係る構造図、配管の配置図等の図面 |
| 二十三 粉じん則別表第二第六号及び第八号に掲げる特定粉じん発生源を有する機械又は設備並びに同表第十四号の型ばらし装置 | 一 粉じん作業(粉じん則第二条第一項第一号の粉じん作業をいう。以下同じ。)の概要 二 機械又は設備の種類、名称、能力、台数及び粉じんの飛散を防止する方法 三 粉じんの飛散を防止する方法として粉じんの発生源を密閉する設備によるときは、密閉の方式、主要構造部分の構造の概要及びその機能 四 前号の方法及び局所排気装置により粉じんの飛散を防止する方法以外の方法によるときは、粉じんの飛散を防止するための設備の型式、主要構造部分の構造の概要及びその能力 | 一 周囲の状況及び四隣との関係を示す図面 二 作業場における主要な機械又は設備の配置を示す図面 三 局所排気装置以外の粉じんの飛散を防止するための設備の構造を示す図面 |
| 二十四 粉じん則第四条又は第二十七条第一項ただし書の規定により設ける局所排気装置又はプッシュプル型換気装置 | 粉じん作業の概要 | 一 周囲の状況及び四隣との関係を示す図面 二 作業場における主要な機械又は設備の配置を示す図面 三 局所排気装置にあつては局所排気装置摘要書(様式第二十五号) 四 プッシュプル型換気装置にあつてはプッシュプル型換気装置摘要書(様式第二十六号) |
| 二十五 石綿等の粉じんが発散する屋内作業場に設ける発散抑制の設備 | 一 石綿等を取り扱い、若しくは試験研究のため製造する業務又は石綿分析用試料等(令第六条第二十三号に規定する石綿分析用試料等をいう。)を製造する業務の概要 二 石綿等の粉じんの発散源を密閉する設備にあつては、密閉の方式、主要構造部分の構造の概要及びその機能 三 全体換気装置にあつては、型式、主要構造部分の構造の概要及びその機能 | 一 周囲の状況及び四隣との関係を示す図面 二 作業場所の全体を示す図面 三 石綿等の粉じんの発散源を密閉する設備又は全体換気装置の図面 四 局所排気装置が設置されている場合にあつては、局所排気装置摘要書(様式第二十五号) 五 プッシュプル型換気装置が設置されている場合にあつてはプッシュプル型換気装置摘要書(様式第二十六号) |
定義第四条第一項第三号
労働安全衛生法施行令(以下「令」という。)第九条の三第一号に掲げる化学設備
わかりやすく言うと
危険物(火薬類を除く)を製造し、若しくは取り扱う設備、又は引火点が六十五度以上の物を引火点以上の温度で製造し、若しくは取り扱う設備で、移動式でないもののことです。アセチレン溶接装置、ガス集合溶接装置、乾燥設備は除きます(施行令第九条の三第一号)。
略称規定第二十四条の三第一項
法第二十五条の二第一項に規定する事業者(以下この章において「事業者」という。)は、次の各号に掲げる機械、器具その他の設備(以下「機械等」という。)を備え付けなければならない。
わかりやすく言うと
機械、器具その他の設備をまとめた呼び名です。この条では、爆発や火災などの際の作業従事者の救護に備えて事業者が備え付ける、空気呼吸器又は酸素呼吸器、ガスの濃度の測定器具、携帯用照明器具などを指します。
略称規定第二十四条の十三第一項
労働者に危険を及ぼし、又は労働者の健康障害をその使用により生ずるおそれのある機械(以下単に「機械」という。)を譲渡し、又は貸与する者(次項において「機械譲渡者等」という。)は、文書の交付等により当該機械に関する次に掲げる事項を…
わかりやすく言うと
使うことによって労働者に危険を及ぼし、又は労働者の健康障害を生ずるおそれのある機械のことです。
定義第三十条第一項第一号
令別表第一に掲げる危険物
わかりやすく言うと
労働安全衛生法施行令別表第一に掲げる、爆発性の物、発火性の物、酸化性の物、引火性の物、可燃性のガスのことです。
略称規定第三十六条第一項第二号
動力により駆動されるプレス機械(以下「動力プレス」という。)の金型、シヤーの刃部又はプレス機械若しくはシヤーの安全装置若しくは安全囲いの取付け、取外し又は調整の業務
定義第三十六条第一項第七号
集材機、架線、搬器、支柱及びこれらに附属する物により構成され、動力を用いて、原木又は薪炭材(以下「原木等」という。)を巻き上げ、かつ、空中において運搬する設備
略称規定第三十六条第一項第二十八号
エックス線装置又はガンマ線照射装置を取り扱う業務(装置の内部にのみ管理区域(電離放射線障害防止規則(昭和四十七年労働省令第四十一号。以下「電離則」という。)第三条第一項に規定する管理区域をいう。次号及び第二十八号の三において同じ。)が存在…
わかりやすく言うと
電離放射線障害防止規則(昭和四十七年労働省令第四十一号)を指す呼び名です。
略称規定第三十六条第一項第二十九号
粉じん障害防止規則(昭和五十四年労働省令第十八号。以下「粉じん則」という。)第二条第一項第三号の特定粉じん作業(設備による注水又は注油をしながら行う粉じん則第三条各号に掲げる作業に該当するものを除く。)に係る業務
わかりやすく言うと
粉じん障害防止規則(昭和五十四年労働省令第十八号)を指す呼び名です。
略称規定第四十二条の五第一項第一号
有機溶剤中毒予防規則(昭和四十七年労働省令第三十六号。以下「有機則」という。)第二十八条の三の二第四項柱書(特定化学物質障害予防規則(昭和四十七年労働省令第三十九号。以下「特化則」という。)第三十六条の五において準用する場合を含む。)…
わかりやすく言うと
有機溶剤中毒予防規則(昭和四十七年労働省令第三十六号)を指す呼び名です。
略称規定第四十二条の五第一項第一号
有機溶剤中毒予防規則(昭和四十七年労働省令第三十六号。以下「有機則」という。)第二十八条の三の二第四項柱書(特定化学物質障害予防規則(昭和四十七年労働省令第三十九号。以下「特化則」という。)第三十六条の五において準用する場合を含む。)…
わかりやすく言うと
特定化学物質障害予防規則(昭和四十七年労働省令第三十九号)を指す呼び名です。
略称規定第四十二条の五第一項第一号
…鉛中毒予防規則(昭和四十七年労働省令第三十七号。以下「鉛則」という。)第五十二条の三の二第四項柱書、特化則第三十六条の三の二第四項柱書又は粉じん則第二十六条の三の二第四項柱書に規定する場合であつて…
わかりやすく言うと
鉛中毒予防規則(昭和四十七年労働省令第三十七号)を指す呼び名です。
定義第五十三条第三項
令第六条第二十三号に規定する石綿等
わかりやすく言うと
石綿と、石綿を重量の〇・一パーセントを超えて含む製剤その他の物のことです(労働安全衛生法施行令第六条第二十三号)。
略称規定第八十五条第一項第一号
…架設通路及び足場以外の機械等(法第三十七条第一項の特定機械等及び令第六条第十四号の型枠支保工(以下「型枠支保工」という。)を除く。)で、六月未満の期間で廃止するもの
わかりやすく言うと
支柱、はり、つなぎ、筋かいなどの部材で組み立てられ、建物のスラブや桁などのコンクリートを打ち込むときに使う型枠を支える仮設の設備のことです(労働安全衛生法施行令第六条第十四号)。
定義第百九十五条第一項・法令全体に適用
事業場附帯の軌道及び車両、動力車、巻上げ機等を含む一切の装置で、動力を用いて軌条により労働者又は荷物を運搬する用に供されるもの(鉄道営業法(明治三十三年法律第六十五号)、鉄道事業法(昭和六十一年法律第九十二号)又は軌道法(大正十年法律第七十六号)の適用を受けるものを除く。)
わかりやすく言うと
事業場に付いている軌道や車両、動力車、巻上げ機などを含む装置で、動力を使いレールで労働者や荷物を運ぶためのもののことです。鉄道営業法、鉄道事業法又は軌道法が適用されるものは除きます。
定義第二百八十七条第一項第四号
熱源を用いて火薬類取締法(昭和二十五年法律第百四十九号)第二条第一項に規定する火薬類以外の物を加熱乾燥する乾燥室及び乾燥器
わかりやすく言うと
熱源を使って物を加熱乾燥する乾燥室と乾燥器のことです。火薬類取締法でいう火薬類(火薬、爆薬、火工品)を乾燥するものは含みません。
定義第三百一条第一項
令第一条第一号に掲げるアセチレン溶接装置
わかりやすく言うと
アセチレン発生器、安全器、導管、吹管などで構成され、溶解アセチレン以外のアセチレンと酸素を使って、金属を溶接し、溶断し、又は加熱する設備のことです(労働安全衛生法施行令第一条第一号)。
略称規定第三百二条第一項
事業者は、アセチレン溶接装置のアセチレン発生器(以下「発生器」という。)については、専用の発生器室(以下「発生器室」という。)内に設けなければならない。
略称規定第三百二条第一項
事業者は、アセチレン溶接装置のアセチレン発生器(以下「発生器」という。)については、専用の発生器室(以下「発生器室」という。)内に設けなければならない。
略称規定第三百八条第一項
事業者は、令第一条第二号のガス集合装置(以下「ガス集合装置」という。)については、火気を使用する設備から五メートル以上離れた場所に設けなければならない。
わかりやすく言うと
十以上の可燃性ガスの容器を導管でつないだ装置か、九以下の容器をつないだ装置で、容器の内容積の合計が水素や溶解アセチレンでは四百リットル以上、その他の可燃性ガスでは千リットル以上のもののことです(労働安全衛生法施行令第一条第二号)。
略称規定第三百八条第二項
事業者は、ガス集合装置で、移動して使用するもの以外のものについては、専用の室(以下「ガス装置室」という。)に設けなければならない。
略称規定第三百十条第一項
事業者は、令第一条第二号に掲げるガス集合溶接装置(以下「ガス集合溶接装置」という。)の配管については、次に定めるところによらなければならない。
わかりやすく言うと
ガス集合装置(可燃性ガスの容器を導管でつないだ一定規模以上の装置)、安全器、圧力調整器、導管、吹管などで構成され、可燃性ガスと酸素を使って金属を溶接し、溶断し、又は加熱する設備のことです(労働安全衛生法施行令第一条第二号)。
略称規定別表第七・この項の中だけ
二十の二 特化則第三十八条の十七第一項の一・三―ブタジエン等(以下この項において「一・三―ブタジエン等」という。)に係る発散抑制の設備(屋外に設置されるものを除く。) 一 一・三―ブタジエン等を製造し、若しくは取り扱う設備から試料を採取し…
わかりやすく言うと
一・三―ブタジエン又は一・四―ジクロロ―二―ブテンと、これらを重量の一パーセントを超えて含有する製剤その他の物のことです(特定化学物質障害予防規則第三十八条の十七)。この表のこの項だけで使う呼び名です。
略称規定別表第七・この項の中だけ
二十の四 特化則第三十八条の十九の一・三―プロパンスルトン等(以下この項において「一・三―プロパンスルトン等」という。)を製造し、又は取り扱う設備及びその附属設備 一 一・三―プロパンスルトン等を製造し…
わかりやすく言うと
一・三―プロパンスルトンと、これを重量の一パーセントを超えて含有する製剤その他の物のことです(特定化学物質障害予防規則第三十八条の十九)。この表のこの項だけで使う呼び名です。
定義別表第七・この項の中だけ
令別表第五第一号の四アルキル鉛
わかりやすく言うと
四メチル鉛、四エチル鉛、一メチル・三エチル鉛、二メチル・二エチル鉛、三メチル・一エチル鉛と、これらを含有するアンチノツク剤のことです(労働安全衛生法施行令別表第五第一号)。
定義別表第七・この項の中だけ
令別表第六の二に掲げる有機溶剤
わかりやすく言うと
労働安全衛生法施行令の別表第六の二に有機溶剤として並べられている、アセトンやイソプロピルアルコールなどの物のことです。
定義別表第七・この項の中だけ
有機則第一条第一項第六号に掲げる有機溶剤業務
わかりやすく言うと
有機溶剤や、これを重量の五パーセントを超えて含む混合物を使って行う塗装、印刷、洗浄、接着のための塗布、乾燥などの業務で、有機溶剤中毒予防規則第一条第一項第六号に並べられたもののことです。
略称規定別表第七・この項の中だけ
十三 有機則第五条又は第六条(特化則第三十八条の八においてこれらの規定を準用する場合を含む。)の有機溶剤の蒸気の発散源を密閉する設備、局所排気装置、プッシュプル型換気装置又は全体換気装置(移動式のものを除く。) 一 有機溶剤業務(有機則第…
わかりやすく言うと
四アルキル鉛をガソリンに混入する業務のことで、四アルキル鉛をストレージタンクに注入する業務を含みます(労働安全衛生法施行令別表第五第二号)。この表のこの項の中で使われます。
定義別表第七・この項の中だけ
同条第二号に掲げる焼結鉱等
わかりやすく言うと
鉛の製錬又は精錬の工程で出る焼結鉱、煙灰、電解スライム及び鉱さいと、銅又は亜鉛の製錬又は精錬の工程で出る煙灰及び電解スライムのことです(鉛中毒予防規則第一条第二号)。
略称規定別表第七・この項の中だけ
十七 令第十五条第一項第十号の特定化学設備(以下この項において「特定化学設備」という。)及びその附属設備 一 特定第二類物質(特化則第二条第一項第三号に掲げる特定第二類物質をいう。以下この項及び次項において同じ。)又は第三類物質(令別表第…
わかりやすく言うと
労働安全衛生法施行令別表第三第二号の第二類物質のうち厚生労働省令で定めるもの、又は同表第三号の第三類物質を製造し、又は取り扱う設備で、移動式以外のもののことです(施行令第十五条第一項第十号)。
定義別表第七・この項の中だけ
特化則第二条第一項第三号に掲げる特定第二類物質
わかりやすく言うと
特定化学物質障害予防規則で第二類物質とされる物のうち、その規則の第二条第一項第三号が並べる物(労働安全衛生法施行令別表第三第二号の一部と、それを含有する物の一部)のことです。
略称規定別表第七・この項の中だけ
十六 特化則第二条第一項第一号に掲げる第一類物質(以下この項において「第一類物質」という。)又は特化則第四条第一項の特定第二類物質等(以下この項において「特定第二類物質等」という。)を製造する設備 一 第一類物質又は特定第二類物質等を製造…
わかりやすく言うと
特定第二類物質とオーラミン等のことで、特定化学物質障害予防規則が製造設備を密閉式の構造にするよう求めている物です(その規則の第四条第一項)。
略称規定別表第七・この項の中だけ
二十の三 特化則第三十八条の十八第一項の硫酸ジエチル等(以下この項において「硫酸ジエチル等」という。)に係る発散抑制の設備(屋外に設置されるものを除く。) 一 硫酸ジエチル等を触媒として取り扱う作業の概要 二 硫酸ジエチル等の蒸気の発散源…
わかりやすく言うと
硫酸ジエチルと、硫酸ジエチルを重量の一パーセントを超えて含む製剤その他の物のことです(特定化学物質障害予防規則第三十八条の十八第一項)。
略称規定別表第七・この項の中だけ
十六 特化則第二条第一項第一号に掲げる第一類物質(以下この項において「第一類物質」という。)又は特化則第四条第一項の特定第二類物質等(以下この項において「特定第二類物質等」という。)を製造する設備 一 第一類物質又は特定第二類物質等を製造…
わかりやすく言うと
労働安全衛生法施行令別表第三第一号に並べられた物のことです(特定化学物質障害予防規則第二条第一項第一号)。
略称規定別表第七・この項の中だけ
十八 特定第二類物質又は特化則第二条第一項第五号に掲げる管理第二類物質(以下この項において「管理第二類物質」という。)のガス、蒸気又は粉じんが発散する屋内作業場に設ける発散抑制の設備(特化則第二条の二第二号又は第四号から第八号までに掲げる…
わかりやすく言うと
特定化学物質障害予防規則で第二類物質(労働安全衛生法施行令別表第三第二号の物)とされる物のうち、特定第二類物質、特別有機溶剤等及びオーラミン等以外の物のことです(その規則の第二条第一項第五号)。
定義別表第七
粉じん則第二条第一項第一号の粉じん作業
わかりやすく言うと
粉じん障害防止規則別表第一に並べられた作業のことです。ただし、粉じんの発散の程度などからみて、その規則の措置を講ずる必要がないと都道府県労働局長が認定した作業は除きます。
定義別表第七・この項の中だけ
鉛則第一条第五号に掲げる鉛業務
わかりやすく言うと
鉛中毒予防規則第一条第五号に並べられた業務のことで、鉛の製錬又は精錬の工程での業務、鉛蓄電池の製造などの工程で鉛等を溶かしたり加工したりする業務、自然換気が不十分な場所でのはんだ付けの業務などが当たります。
定義別表第七・この項の中だけ
鉛則第一条第一号に掲げる鉛等
わかりやすく言うと
鉛、鉛合金、鉛化合物と、これらと他の物との混合物のことです。焼結鉱、煙灰、電解スライム及び鉱さいは除きます(鉛中毒予防規則第一条第一号)。