When carrying out the construction work of tunnels, etc., the employer must provide the apparatuses for evacuation listed in the following items in accordance with the classification listed in each item at appropriate locations, in order to evacuate persons engaged in work in the case of cave-in, inundation, gas explosion, fire or other emergencies, and inform the persons engaged in work concerned of the locations of the apparatuses and the method of using the apparatuses:
for the tunnels, etc., other than those where flammable gas exists and where there is a risk of explosion or fire (excluding the case listed in item (iii)), and when the distance to the working face has reached 100 m:portable lighting apparatuses such as flashlights (hereinafter called "portable illumination apparatuses" in this Article) and other apparatuses necessary for evacuation;
for the tunnels, etc., where flammable gas exists and where there is a risk of explosion or fire (excluding the case listed in the following item), and when the distance to the working face has reached 100 m:respirators such as survival equipment against carbon monoxide (hereinafter referred to as "respirators" in this Article), portable illumination apparatuses and other apparatuses necessary for evacuation; and
when the distance to the working face has reached 500 m:respirators, portable illumination apparatuses and other apparatuses necessary for evacuation.
As regards the respirators set forth in the preceding paragraph, the employer must provide the number of respirators equal to or more than the number of persons engaged in work working at the same time (excluding persons engaged in work in the vicinity of the entrance; the same applies in the following paragraph), and maintain their functioning and cleanliness at all times.
As regards the portable illumination apparatuses set forth in paragraph (1), the employer must provide the number of apparatuses equal to or more than the number of persons engaged in work working at the same time, and maintain them to effectively function at all times; provided, however, that this does not apply in the case referred to in item (i) of the same paragraph, when measures to secure illumination necessary for the evacuation of persons engaged in work working at the same time as a group have been taken.
定義第二十四条の六第一項
ずい道及びたて坑以外の坑(採石法(昭和二十五年法律第二百九十一号)第二条に規定する岩石の採取のためのものを除く。)
わかりやすく言うと
ずい道と、たて坑以外の坑をまとめた呼び名です。ただし、採石法で定める花こう岩などの岩石を採取するための坑は含みません。
定義第二百五十八条第一項
令別表第一第五号に掲げる可燃性のガス
わかりやすく言うと
水素、アセチレン、エチレン、メタン、エタン、プロパン、ブタンその他の、温度十五度、一気圧で気体である可燃性の物のことです(労働安全衛生法施行令別表第一第五号)。
略称規定第三百八十九条の九第一項第一号・この款の中だけ
出入口から切羽までの距離(以下この款において「切羽までの距離」という。)が百メートルに達したとき(次号に掲げる場合を除く。) サイレン、非常ベル等の警報用の設備(以下この条において「警報設備」という。)
わかりやすく言うと
ずい道等の出入口から、掘り進めている先端の面(切羽)までの距離のことです。
略称規定第三百八十九条の十第一項第一号・この条の中だけ
可燃性ガスが存在して爆発又は火災が生ずるおそれのあるずい道等以外のずい道等にあつては、切羽までの距離が百メートルに達したとき(第三号に掲げる場合を除く。) 懐中電灯等の携帯用照明器具(以下この条において「携帯用照明器具」という。)その他避…
わかりやすく言うと
懐中電灯などの持ち運べる照明器具のことで、この条で使う呼び名です。
略称規定第三百八十九条の十第一項第二号・この条の中だけ
可燃性ガスが存在して爆発又は火災が生ずるおそれのあるずい道等にあつては、切羽までの距離が百メートルに達したとき(次号に掲げる場合を除く。) 一酸化炭素用自己救命器等の呼吸用保護具(以下この条において「呼吸用保護具」という。)…
わかりやすく言うと
一酸化炭素用自己救命器などの呼吸用の保護具のことで、この条で使う呼び名です。