Article 304Storeroom

第三百四条(格納室)

As regards movable acetylene welding equipment, notwithstanding the provisions of Article 302, paragraph (1), the employer must store the equipment in a dedicated storeroom when it is not used; provided, however, that this does not apply when storing the equipment after its gas bell is removed and the generator is washed.

事業者は、移動式のアセチレン溶接装置については、第三百二条第一項の規定にかかわらず、これを使用しないときは、専用の格納室に収容しなければならない。ただし、気鐘を分離し、発生器を洗浄した後保管するときは、この限りでない。

As regards the storeroom referred to in the preceding paragraph, the employer must construct it by using fire-proof materials such as iron plate-lined lumber and slate-lined lumber.

事業者は、前項の格納室については、木骨鉄板張、木骨スレート張等耐火性の構造としなければならない。