Search

Search provisions, jump to a law or an article

1 article

Article 569

第五百六十九条

As regards log scaffoldings, the employer must not use them unless they conform to the following requirements:

事業者は、丸太足場については、次に定めるところに適合したものでなければ使用してはならない。

to have the interval between standards 2.5 m or less, and provide the first ledger over the ground at a place having a height of 3 m or less;

建地の間隔は、二・五メートル以下とし、地上第一の布は、三メートル以下の位置に設けること。

for the leg part of standards, to take measures such as embedding the foot of standards underground, providing bridge batten of foot posts, and using sills in order to prevent standards from sliding or settling;

建地の脚部には、その滑動又は沈下を防止するため、建地の根本を埋め込み、根がらみを設け、皿板を使用する等の措置を講ずること。

when the couplings of standards are lap joints, to band the joining parts at two locations or more with overlapping of 1 m or more; when the couplings of standards are butt joints, to construct the standards with two logs, or band the joining part at four locations or more with a splint having a length of 1.8 m or more;

建地の継手が重合せ継手の場合には、接続部において、一メートル以上を重ねて二箇所以上において縛り、建地の継手が突合せ継手の場合には、二本組の建地とし、又は一・八メートル以上の添木を用いて四箇所以上において縛ること。

for the joining parts and intersecting parts of standards, ledgers, brackets, etc., to be firmly bound with wires or other strong materials;

建地、布、腕木等の接続部及び交差部は、鉄線その他の丈夫な材料で堅固に縛ること。

to reinforce log scaffoldings using diagonal bracing;

筋かいで補強すること。

for single row scaffolding, double row scaffolding or cantilever scaffolding, to provide ties to wall or stays that conform to the following requirements:

一側足場、本足場又は張出し足場であるものにあつては、次に定めるところにより、壁つなぎ又は控えを設けること。

the interval to be of 5.5 m or less in the vertical direction and 7.5 m or less in the horizontal direction;

間隔は、垂直方向にあつては五・五メートル以下、水平方向にあつては七・五メートル以下とすること。

to make the ties to wall or stays solid with steel pipes, logs, etc.; and

鋼管、丸太等の材料を用いて堅固なものとすること。

when the ties to wall or stays are composed of tension components and compression components, the interval between these components are to be within 1 m.

引張材と圧縮材とで構成されているものであるときは、引張材と圧縮材との間隔は、一メートル以内とすること。

The provisions of item (i) of the preceding paragraph do not apply to the case where it is difficult to conform to the requirements of the provisions of the item due to the necessity of the work and the parts are reinforced with bent ledgers, two logs combined, etc.

前項第一号の規定は、作業の必要上同号の規定により難い部分がある場合において、なべつり、二本組等により当該部分を補強したときは、適用しない。

The provisions of paragraph (1), item (vi) do not apply when ties to wall or stays are removed for work such as mounting window frames or finishing wall surfaces, or in other cases where it is unavoidable due to the necessity of the work, if measures are taken in order to prevent the scaffolding from collapsing, such as providing diagonal components to standards or ledgers in lieu of the ties to wall or stays.

第一項第六号の規定は、窓枠の取付け、壁面の仕上げ等の作業のため壁つなぎ又は控えを取り外す場合その他作業の必要上やむを得ない場合において、当該壁つなぎ又は控えに代えて、建地又は布に斜材を設ける等当該足場の倒壊を防止するための措置を講ずるときは、適用しない。

Read this with the articles around it

© 2026 japanlaw.orgA copy for reading and reference — not an official source, and not legal advice. Only the Japanese text published by the government has legal effect.Run by Genjido LLC (源氏道合同会社) · contact@genjido.comContactSourcesTermsPrivacy