As regards steel pipe scaffoldings composed of members other than those listed in Appended Table 8, items (i) through (iii) of the Order or steel pipes other than those conforming to the standard for steel pipes for single-pipe scaffolding, the employer must not use them unless the value of the maximum bending moment calculated with each fulcrum interval regarded as a simple beam is equal to or less than the value obtained by multiplying the section modulus of the steel pipe by 1/1.5 of the yield point value of the material of the steel pipe (for those whose yield point value is unknown, 1/2 of the tensile strength value) and by the coefficient listed in the right column of the following table in accordance with the ratio of thickness to outer diameter of steel pipe listed in the left column of the same table (when joints exist, 3/4 of this value), in addition to conforming to the requirements set forth in Article 570, paragraph (1).
| Ratio of Thickness to Outer Diameter of Steel Pipe | Coefficient |
| Thickness of 1/14 or more of outer diameter | 1 |
| Thickness of 1/20 or more and less than 1/14 of outer diameter | 0.9 |
| Thickness of 1/31 or more and less than 1/20 of outer diameter | 0.8 |