Search

Search provisions, jump to a law or an article

This text is not in force yetIt on 1 January 2027, in 43 days

Read the text in force →

Ordinance on Industrial Safety and Health

労働安全衛生規則(ろうどうあんぜんえいせいきそく)

Chapter X Passages and Scaffoldings (Articles 568 to 575)

The law as Ministerial Order Partially Amending the Ordinance on Industrial Safety and Health and the Ordinance for Enforcement of the Act on Ensuring the Proper Operation of Worker Dispatching Services and Protecting Dispatched Workers (Ministry of Health, Labour and Welfare Order No. 120 of 2025) leaves it, with the words it changes marked.

The main text is read a page at a time: a chapter to a page, and a long chapter in runs of articles. The whole main text, and the supplementary provisions and appended tables this amendment changes. Those it leaves untouched are on the page for the text in force.

How the changes are shown

Underlined: words the amendment adds. A bar: where it removes words.Underlined: words the amendment adds. Struck through: the words it removes.Underlined: words the amendment adds. Struck through: the words it removes.

Article 568第五百六十八条

Inspection of Hanging Scaffolding(つり足場の点検)
Article 568, paragraph (1)

When carrying out work on hanging scaffolding, the employer must designate an inspector and have the person inspect the matters listed in paragraph (2), items (i) through (v), item (vii) and item (ix) of the preceding Article before commencing the work for the day, and when having found any abnormality, must immediately make repairs.

事業者は、つり足場における作業を行うときは、点検者を指名して、その日の作業を開始する前に、前条第二項第一号から第五号まで、第七号及び第九号に掲げる事項について点検させ、異常を認めたときは、直ちに補修しなければならない。

Subsection 3 Log Scaffoldings第三款 丸太足場

Article 569第五百六十九条

Article 569, paragraph (1)

As regards log scaffoldings, the employer must not use them unless they conform to the following requirements:

事業者は、丸太足場については、次に定めるところに適合したものでなければ使用してはならない。

Article 569, paragraph (1), item (i)

to have the interval between standards 2.5 m or less, and provide the first ledger over the ground at a place having a height of 3 m or less;

建地の間隔は、二・五メートル以下とし、地上第一の布は、三メートル以下の位置に設けること。

Article 569, paragraph (1), item (ii)

for the leg part of standards, to take measures such as embedding the foot of standards underground, providing bridge batten of foot posts, and using sills in order to prevent standards from sliding or settling;

建地の脚部には、その滑動又は沈下を防止するため、建地の根本を埋め込み、根がらみを設け、皿板を使用する等の措置を講ずること。

Article 569, paragraph (1), item (iii)

when the couplings of standards are lap joints, to band the joining parts at two locations or more with overlapping of 1 m or more; when the couplings of standards are butt joints, to construct the standards with two logs, or band the joining part at four locations or more with a splint having a length of 1.8 m or more;

建地の継手が重合せ継手の場合には、接続部において、一メートル以上を重ねて二箇所以上において縛り、建地の継手が突合せ継手の場合には、二本組の建地とし、又は一・八メートル以上の添木を用いて四箇所以上において縛ること。

Article 569, paragraph (1), item (iv)

for the joining parts and intersecting parts of standards, ledgers, brackets, etc., to be firmly bound with wires or other strong materials;

建地、布、腕木等の接続部及び交差部は、鉄線その他の丈夫な材料で堅固に縛ること。

Article 569, paragraph (1), item (v)

to reinforce log scaffoldings using diagonal bracing;

筋かいで補強すること。

Article 569, paragraph (1), item (vi)

for single row scaffolding, double row scaffolding or cantilever scaffolding, to provide ties to wall or stays that conform to the following requirements:

一側足場、本足場又は張出し足場であるものにあつては、次に定めるところにより、壁つなぎ又は控えを設けること。

Article 569, paragraph (1), item (vi), (a)

the interval to be of 5.5 m or less in the vertical direction and 7.5 m or less in the horizontal direction;

間隔は、垂直方向にあつては五・五メートル以下、水平方向にあつては七・五メートル以下とすること。

Article 569, paragraph (1), item (vi), (b)

to make the ties to wall or stays solid with steel pipes, logs, etc.; and

鋼管、丸太等の材料を用いて堅固なものとすること。

Article 569, paragraph (1), item (vi), (c)

when the ties to wall or stays are composed of tension components and compression components, the interval between these components are to be within 1 m.

引張材と圧縮材とで構成されているものであるときは、引張材と圧縮材との間隔は、一メートル以内とすること。

Article 569, paragraph (2)

The provisions of item (i) of the preceding paragraph do not apply to the case where it is difficult to conform to the requirements of the provisions of the item due to the necessity of the work and the parts are reinforced with bent ledgers, two logs combined, etc.

前項第一号の規定は、作業の必要上同号の規定により難い部分がある場合において、なべつり、二本組等により当該部分を補強したときは、適用しない。

Article 569, paragraph (3)

The provisions of paragraph (1), item (vi) do not apply when ties to wall or stays are removed for work such as mounting window frames or finishing wall surfaces, or in other cases where it is unavoidable due to the necessity of the work, if measures are taken in order to prevent the scaffolding from collapsing, such as providing diagonal components to standards or ledgers in lieu of the ties to wall or stays.

第一項第六号の規定は、窓枠の取付け、壁面の仕上げ等の作業のため壁つなぎ又は控えを取り外す場合その他作業の必要上やむを得ない場合において、当該壁つなぎ又は控えに代えて、建地又は布に斜材を設ける等当該足場の倒壊を防止するための措置を講ずるときは、適用しない。

Subsection 4 Steel Pipe Scaffoldings第四款 鋼管足場

Article 570第五百七十条

Steel Pipe Scaffoldings(鋼管足場)
Article 570, paragraph (1)

As regards steel pipe scaffoldings, the employer must not use them unless they conform to the following requirements:

事業者は、鋼管足場については、次に定めるところに適合したものでなければ使用してはならない。

Article 570, paragraph (1), item (i)

for the leg part of the scaffoldings (excluding movable scaffoldings with casters), to take measures such as providing the bridge batten of foot posts with base fittings, and plankings, square timbers, etc., in order to prevent the scaffolding from sliding or subsiding;

足場(脚輪を取り付けた移動式足場を除く。)の脚部には、足場の滑動又は沈下を防止するため、ベース金具を用い、かつ、敷板、敷角等を用い、根がらみを設ける等の措置を講ずること。

Article 570, paragraph (1), item (ii)

for movable scaffolding with casters, to take measures such as securely fixing the casters with a brake, or other brakes, pawl, etc. or fastening a part of the scaffolding to a solid building, in order to prevent scaffoldings from moving unexpectedly;

脚輪を取り付けた移動式足場にあつては、不意に移動することを防止するため、ブレーキ、歯止め等で脚輪を確実に固定させ、足場の一部を堅固な建設物に固定させる等の措置を講ずること。

Article 570, paragraph (1), item (iii)

to securely join or fasten the joining parts or intersecting parts of steel pipes with suitable fittings;

鋼管の接続部又は交差部は、これに適合した附属金具を用いて、確実に接続し、又は緊結すること。

Article 570, paragraph (1), item (iv)

to reinforce the scaffolding with bracings;

筋かいで補強すること。

Article 570, paragraph (1), item (v)

for single row scaffolding, double row scaffolding or cantilever scaffolding, to provide ties to wall or stays that conform to the following requirement:

一側足場、本足場又は張出し足場であるものにあつては、次に定めるところにより、壁つなぎ又は控えを設けること。

Article 570, paragraph (1), item (v), (a)

the interval is to be equal to or less than the value listed in the right column of the following table in accordance with the type of steel pipe scaffolding listed in the left column of the same table;

Type of Steel Pipe ScaffoldingInterval (Unit: m)
Vertical DirectionHorizontal Direction
Single pipe scaffolding55.5
Prefabricated scaffolding (excluding those less than 5 m in height)98

間隔は、次の表の上欄に掲げる鋼管足場の種類に応じ、それぞれ同表の下欄に掲げる値以下とすること。

鋼管足場の種類間隔(単位メートル)
垂直方向水平方向
単管足場五五・五
わく組足場(高さが五メートル未満のものを除く。)九八
Article 570, paragraph (1), item (v), (b)

to make the scaffolding strong with materials such as steel pipes and logs;

鋼管、丸太等の材料を用いて、堅固なものとすること。

Article 570, paragraph (1), item (v), (c)

when the scaffoldings are composed of tension components and compression components, the interval between these components are to be within 1 m; and

引張材と圧縮材とで構成されているものであるときは、引張材と圧縮材との間隔は、一メートル以内とすること。

Article 570, paragraph (1), item (vi)

when a scaffolding is to be installed in the vicinity of an overhead power line, to take measures to prevent contact with the overhead power line such as moving the overhead power line or installing protecting equipment for insulating.

架空電路に近接して足場を設けるときは、架空電路を移設し、架空電路に絶縁用防護具を装着する等架空電路との接触を防止するための措置を講ずること。

Article 570, paragraph (2)

The provisions of paragraph (3) of the preceding Article apply mutatis mutandis to item (v) of the preceding paragraph. In this case, the term "paragraph (1), item (vi)" in paragraph (3) of the preceding Article is deemed to be replaced with " Article 570, paragraph (1), item (v)."

前条第三項の規定は、前項第五号の規定の適用について、準用する。この場合において、前条第三項中「第一項第六号」とあるのは、「第五百七十条第一項第五号」と読み替えるものとする。

Article 571第五百七十一条

Steel Pipe Scaffoldings Using Members, etc. Listed in Appended Table 8, item (i) of the Order(令別表第八第一号に掲げる部材等を用いる鋼管足場)
Article 571, paragraph (1)

As regards steel pipe scaffoldings composed of members listed in Appended Table 8, item (i) of the Order or steel pipes conforming to the standard for steel pipes for single-pipe scaffolding, the employer must not use them unless they conform to the requirements set forth in items (i) through (iv) for single pipe scaffoldings and in items (v) through (vii) for prefabricated scaffoldings, in addition to the requirements set forth in paragraph (1) of the preceding Article:

事業者は、令別表第八第一号に掲げる部材又は単管足場用鋼管規格に適合する鋼管を用いて構成される鋼管足場については、前条第一項に定めるところによるほか、単管足場にあつては第一号から第四号まで、わく組足場にあつては第五号から第七号までに定めるところに適合したものでなければ使用してはならない。

Article 571, paragraph (1), item (i)

the intervals of the standards are to be of 1.85 m or less in the direction of the crossbeam and 1.5 m or less in the direction of the beam;

建地の間隔は、けた行方向を一・八五メートル以下、はり間方向は一・五メートル以下とすること。

Article 571, paragraph (1), item (ii)

to provide the first ledger above the ground at the height of 2 m or lower;

地上第一の布は、二メートル以下の位置に設けること。

Article 571, paragraph (1), item (iii)

for the portion of the standards exceeding 31 m as measured from the highest part of the standards, to use two steel pipes combined; provided, however, that this does not apply when the design load acting on the lower end of the standard (meaning the load obtained by adding the maximum loading capacity of the work floor to the load equivalent to the weight of the scaffolding) does not exceed the maximum working load of the standard (meaning a load that is one-half or less of the load that leads to the breaking of the standard);

建地の最高部から測つて三十一メートルを超える部分の建地は、鋼管を二本組とすること。ただし、建地の下端に作用する設計荷重(足場の重量に相当する荷重に、作業床の最大積載荷重を加えた荷重をいう。)が当該建地の最大使用荷重(当該建地の破壊に至る荷重の二分の一以下の荷重をいう。)を超えないときは、この限りでない。

Article 571, paragraph (1), item (iv)

to limit the loading capacity between the standards to 400 kg;

建地間の積載荷重は、四百キログラムを限度とすること。

Article 571, paragraph (1), item (v)

to provide the horizontal components at the top level and for each fifth level or less;

最上層及び五層以内ごとに水平材を設けること。

Article 571, paragraph (1), item (vi)

to take measures to prevent the beam frames and bracket frames from moving laterally with horizontal bracings; and

はりわく及び持送りわくは、水平筋かいその他によつて横振れを防止する措置を講ずること。

Article 571, paragraph (1), item (vii)

when the scaffolding has a height exceeding 20 m, and when the work involves carrying heavy materials, the main frame is to be the height of 2 m or less, and the interval is to be 1.85 m or less.

高さ二十メートルを超えるとき及び重量物の積載を伴う作業を行うときは、使用する主わくは、高さ二メートル以下のものとし、かつ、主わく間の間隔は一・八五メートル以下とすること。

Article 571, paragraph (2)

The provisions of item (i) or item (iv) of the preceding paragraph do not apply when it is difficult to comply with the provisions due to necessity of work and when the employer takes the measures prescribed in the following Article for the value of the maximum bending moment obtained by the calculation supposing that the components between each fulcrum as a simple beam structure.

前項第一号又は第四号の規定は、作業の必要上これらの規定により難い場合において、各支点間を単純ばりとして計算した最大曲げモーメントの値に関し、事業者が次条に定める措置を講じたときは、適用しない。

Article 571, paragraph (3)

The provisions of paragraph (1), item (ii) do not apply when it is difficult to comply with the provisions due to the necessity of work and when the parts are reinforced with two steel pipes combined, etc.

第一項第二号の規定は、作業の必要上同号の規定により難い部分がある場合において、二本組等により当該部分を補強したときは、適用しない。

Article 572第五百七十二条

Steel Pipe Scaffoldings Using Members, etc. Other Than Those Listed in Appended Table 8, items (i) through (iii) of the Order(令別表第八第一号から第三号までに掲げる部材以外の部材等を用いる鋼管足場)
Article 572, paragraph (1)

As regards steel pipe scaffoldings composed of members other than those listed in Appended Table 8, items (i) through (iii) of the Order or steel pipes other than those conforming to the standard for steel pipes for single-pipe scaffolding, the employer must not use them unless the value of the maximum bending moment calculated with each fulcrum interval regarded as a simple beam is equal to or less than the value obtained by multiplying the section modulus of the steel pipe by 1/1.5 of the yield point value of the material of the steel pipe (for those whose yield point value is unknown, 1/2 of the tensile strength value) and by the coefficient listed in the right column of the following table in accordance with the ratio of thickness to outer diameter of steel pipe listed in the left column of the same table (when joints exist, 3/4 of this value), in addition to conforming to the requirements set forth in Article 570, paragraph (1).

Ratio of Thickness to Outer Diameter of Steel PipeCoefficient
Thickness of 1/14 or more of outer diameter1
Thickness of 1/20 or more and less than 1/14 of outer diameter0.9
Thickness of 1/31 or more and less than 1/20 of outer diameter0.8

事業者は、令別表第八第一号から第三号までに掲げる部材以外の部材又は単管足場用鋼管規格に適合する鋼管以外の鋼管を用いて構成される鋼管足場については、第五百七十条第一項に定めるところによるほか、各支点間を単純ばりとして計算した最大曲げモーメントの値が、鋼管の断面係数に、鋼管の材料の降伏強さの値(降伏強さの値が明らかでないものについては、引張強さの値の二分の一の値)の一・五分の一及び次の表の上欄に掲げる鋼管の肉厚と外径との比に応じ、それぞれ同表の下欄に掲げる係数を乗じて得た値(継手のある場合には、この値の四分の三)以下のものでなければ使用してはならない。

鋼管の肉厚と外径との比係数
肉厚が外径の十四分の一以上一
肉厚が外径の二十分の一以上十四分の一未満〇・九
肉厚が外径の三十一分の一以上二十分の一未満〇・八

Article 573第五百七十三条

Distinction of Strength of Steel Pipes(鋼管の強度の識別)
Article 573, paragraph (1)

When using steel pipes with the same or similar outer diameter and thickness which differ in strength at the same workplace, in order to prevent dangers to workers due to confused use of the steel pipes, the employer must take measures to distinguish the strength such as coloring or affixing symbols, to the pipe surface, etc.

事業者は、外径及び肉厚が同一であり、又は近似している鋼管で、強度が異なるものを同一事業場で使用するときは、鋼管の混用による労働者の危険を防止するため、鋼管に色又は記号を付する等の方法により、鋼管の強度を識別することができる措置を講じなければならない。

Article 573, paragraph (2)

The measure referred to in the preceding paragraph must not be the distinction by color only.

前項の措置は、色を付する方法のみによるものであつてはならない。

Subsection 5 Hanging Scaffoldings第五款 つり足場

Article 574第五百七十四条

Hanging Scaffoldings(つり足場)
Article 574, paragraph (1)

As regards hanging scaffoldings, the employer must not use them unless they conform to the following requirements:

事業者は、つり足場については、次に定めるところに適合したものでなければ使用してはならない。

Article 574, paragraph (1), item (i)

to not use hanging wire ropes falling under any of the following sub-items:

つりワイヤロープは、次のいずれかに該当するものを使用しないこと。

Article 574, paragraph (1), item (i), (a)

those with 10% or more of element wires (excluding filler wires; hereinafter the same applies in this item) of which are cut in one lay of wire ropes;

ワイヤロープ一よりの間において素線(フイラ線を除く。以下この号において同じ。)の数の十パーセント以上の素線が切断しているもの

Article 574, paragraph (1), item (i), (b)

those with reduction ratio of a diameter exceeding 7% of the nominal diameter;

直径の減少が公称径の七パーセントを超えるもの

Article 574, paragraph (1), item (i), (c)

those with kinks;

キンクしたもの

Article 574, paragraph (1), item (i), (d)

those with marked deformation or corrosion;

著しい形崩れ又は腐食があるもの

Article 574, paragraph (1), item (ii)

to not use hanging chains falling under any of the following sub-items:

つり鎖は、次のいずれかに該当するものを使用しないこと。

Article 574, paragraph (1), item (ii), (a)

those with the elongation exceeding 5% of the original length at the time of manufacture;

伸びが、当該つり鎖が製造されたときの長さの五パーセントを超えるもの

Article 574, paragraph (1), item (ii), (b)

those with a reduction ratio of the diameter of links of the hanging chains exceeding 10% of the original diameter at the time of manufacture;

リンクの断面の直径の減少が、当該つり鎖が製造されたときの当該リンクの断面の直径の十パーセントを超えるもの

Article 574, paragraph (1), item (ii), (c)

those with cracks;

亀裂があるもの

Article 574, paragraph (1), item (iii)

to not use hanging steel wires and hanging steel belts with marked damage, deformation or corrosion;

つり鋼線及びつり鋼帯は、著しい損傷、変形又は腐食のあるものを使用しないこと。

Article 574, paragraph (1), item (iv)

to not use hanging fiber ropes falling under any of the following sub-items:

つり繊維索は、次のいずれかに該当するものを使用しないこと。

Article 574, paragraph (1), item (iv), (a)

those with cut strands;

ストランドが切断しているもの

Article 574, paragraph (1), item (iv), (b)

those with marked damage or corrosion;

著しい損傷又は腐食があるもの

Article 574, paragraph (1), item (v)

to securely fasten one end of the hanging wire ropes, hanging chains, hanging steel wires, hanging steel belts or hanging fiber ropes to the scaffolding girder, stirrup, etc., and the other end to projected girders, anchor bolts, girders of building, etc.;

つりワイヤロープ、つり鎖、つり鋼線、つり鋼帯又はつり繊維索は、その一端を足場桁、スターラツプ等に、他端を突りよう、アンカーボルト、建築物のはり等にそれぞれ確実に取り付けること。

Article 574, paragraph (1), item (vi)

the work floor is to be with a width of 40 cm or more, and without clearance between the floor boards;

作業床は、幅を四十センチメートル以上とし、かつ、隙間がないようにすること。

Article 574, paragraph (1), item (vii)

to fasten the floor materials to the scaffolding girder, stirrup, etc., in order to prevent them from being displaced or coming off;

床材は、転位し、又は脱落しないように、足場桁、スターラツプ等に取り付けること。

Article 574, paragraph (1), item (viii)

to take measures in order to prevent movement or displacement such as providing stays to the scaffolding girders, stirrups, work floors, etc.; and

足場桁、スターラツプ、作業床等に控えを設ける等動揺又は転位を防止するための措置を講ずること。

Article 574, paragraph (1), item (ix)

for shelf scaffoldings, to securely connect or fasten the joining parts and intersecting parts of girders with steel wires, couplings or clamps.

棚足場であるものにあつては、桁の接続部及び交差部は、鉄線、継手金具又は緊結金具を用いて、確実に接続し、又は緊結すること。

Article 574, paragraph (2)

The provisions of item (vi) of the preceding paragraph do not apply when measures are taken to prevent dangers to workers due to falling or falling of objects such as installing a net or a sheet under the work floor or sideways of the work floor.

前項第六号の規定は、作業床の下方又は側方に網又はシートを設ける等墜落又は物体の落下による労働者の危険を防止するための措置を講ずるときは、適用しない。

Article 575第五百七十五条

Prohibition of Work(作業禁止)
Article 575, paragraph (1)

The employer must not have workers use a stepladder, a ladder, etc., on hanging scaffolding.

事業者は、つり足場の上で、脚立、はしご等を用いて労働者に作業させてはならない。

© 2026 japanlaw.orgA copy for reading and reference — not an official source, and not legal advice. Only the Japanese text published by the government has legal effect.Run by Genjido LLC (源氏道合同会社) · contact@genjido.comContactSourcesTermsPrivacy