Article 604Illuminance

第六百四条(照度)

The employer must conform illuminance on the working face of the place where workers are regularly engaged in work to the standards listed in the right column of the following Table in accordance with the type of work listed in the left column of the same Table; provided, however that this does not apply to workshops where photosensitive materials are handled, a workshop in a pit, and other workshops where special work is carried out.

Division of WorkStandards
Precision work300 luces or more
Ordinary work150 luces or more
Rough work70 luces or more

事業者は、労働者を常時就業させる場所の作業面の照度を、次の表の上欄に掲げる作業の区分に応じて、同表の下欄に掲げる基準に適合させなければならない。ただし、感光材料を取り扱う作業場、坑内の作業場その他特殊な作業を行なう作業場については、この限りでない。

作業の区分基準
精密な作業三百ルクス以上
普通の作業百五十ルクス以上
粗な作業七十ルクス以上