労働安全衛生規則(ろうどうあんぜんえいせいきそく)

Chapter III Concrete Form Shoring (Articles 237 to 241)

The law as Ministerial Order Partially Amending the Ordinance on Industrial Safety and Health (Ministry of Health, Labour and Welfare Order No. 112 of 2026) leaves it, with the words it changes marked.

The main text is read a page at a time: a chapter to a page, and a long chapter in runs of articles. The whole main text, and the supplementary provisions and appended tables this amendment changes. Those it leaves untouched are on the page for the text in force.

How the changes are shown

Underlined: words the amendment adds. A bar: where it removes words.Underlined: words the amendment adds. Struck through: the words it removes.Underlined: words the amendment adds. Struck through: the words it removes.

Chapter III Concrete Form Shoring第三章 型わく支保工

Section 1 Materials第一節 材料等

Article 237第二百三十七条

Material(材料)
Article 237, paragraph (1)

As regards materials for concrete form shoring, the employer must not use those with marked damage, deformation or corrosion.

事業者は、型わく支保工の材料については、著しい損傷、変形又は腐食があるものを使用してはならない。

Article 238第二百三十八条

Steel Used for the Main Part(主要な部分の鋼材)
Article 238, paragraph (1)

As regards steel materials for the main parts of supports, girders or supporting members for girders used for concrete form shoring, the employer must not use those materials unless they conform to the Japanese Industrial Standard G 3101 (Rolled Steel for General Structure), the Japanese Industrial Standard G 3106 (Rolled Steel for Welded Structure), the Japanese Industrial Standard G 3444 (Carbon Steel Tubes for General Structural Purposes), or the Japanese Industrial Standard G 3350 (Cold-formed Light Gauge Steels for Construction Structure), or those materials of which the value of tensile strength is 330 N/mm2 or more in the test conducted by the method prescribed by the Japanese Industrial Standard Z2241 (Method of Tensile Test for Metallic Materials), and which have elongation listed in the right column of the following Table in accordance with the type of the steel materials listed in the left column and the value of the tensile strength listed in the middle column of the same Table:

Type of Steel MaterialTensile Strength (Unit: N/mm2)Elongation (Unit: Percent)
Steel pipe330 or more and less than 40025 or more
400 or more and less than 49020 or more
490 or more10 or more
Steel plate, shape steel, flat steel, or light gauge steel330 or more and less than 40021 or more
400 or more and less than 49016 or more
490 or more and less than 59012 or more
590 or more8 or more
Bar steel330 or more and less than 40025 or more
400 or more and less than 49020 or more
490 or more18 or more

事業者は、型わく支保工に使用する支柱、はり又ははりの支持物の主要な部分の鋼材については、日本産業規格G三一〇一(一般構造用圧延鋼材)、日本産業規格G三一〇六(溶接構造用圧延鋼材)、日本産業規格G三四四四(一般構造用炭素鋼鋼管)若しくは日本工業規格G三三五〇(建築構造用冷間成形軽量形鋼)に定める規格に適合するもの又は日本産業規格Z二二四一(金属材料引張試験方法)に定める方法による試験において、引張強さの値が三百三十ニュートン毎平方ミリメートル以上で、かつ、伸びが次の表の上欄に掲げる鋼材の種類及び同表の中欄に掲げる引張強さの値に応じ、それぞれ同表の下欄に掲げる値となるものでなければ、使用してはならない。

鋼材の種類引張強さ(単位 ニュートン毎平方ミリメートル)伸び(単位 パーセント)
鋼管三百三十以上四百未満二十五以上
四百以上四百九十未満二十以上
四百九十以上十以上
鋼板、形鋼、平鋼又は軽量形鋼三百三十以上四百未満二十一以上
四百以上四百九十未満十六以上
四百九十以上五百九十未満十二以上
五百九十以上八以上
棒鋼三百三十以上四百未満二十五以上
四百以上四百九十未満二十以上
四百九十以上十八以上

Article 239第二百三十九条

Structure of Concrete Form Shoring(型わく支保工の構造)
Article 239, paragraph (1)

As regards a concrete form shoring, the employer must not use the shoring unless it has a solid structure in accordance with the configuration of the concrete form, method of placing concrete, etc.

事業者は、型わく支保工については、型わくの形状、コンクリートの打設の方法等に応じた堅固な構造のものでなければ、使用してはならない。

Section 2 Measures in the Case of Assembling Concrete Form Shoring第二節 組立て等の場合の措置

Article 240第二百四十条

Assembly Drawing(組立図)
Article 240, paragraph (1)

When assembling concrete form shoring, the employer must create an assembly drawing and assemble the concrete form shoring according to the assembly drawing.

事業者は、型わく支保工を組み立てるときは、組立図を作成し、かつ、当該組立図により組み立てなければならない。

Article 240, paragraph (2)

The assembly drawing set forth in the preceding paragraph must indicate the arrangement, method of connection and size of the components such as supports, girders, ties and diagonal bracings.

前項の組立図は、支柱、はり、つなぎ、筋かい等の部材の配置、接合の方法及び寸法が示されているものでなければならない。

Article 240, paragraph (3)

The design of the concrete form shoring pertaining to the assembly drawing set forth in paragraph (1) must comply with the requirements set forth in the following items:

第一項の組立図に係る型枠支保工の設計は、次に定めるところによらなければならない。

Article 240, paragraph (3), item (i)

when the support, the girder or the supporting member of the girder (hereinafter referred to as "support, etc." in this Article) does not have a combined structure, the value of the stress produced on the support, etc., by the design load (meaning adding the load equivalent to the weight of things supported by concrete form shoring to the load of 150 kg or more per 1 m2 of the concrete form; hereinafter the same applies in this Article) does not exceed the value of the allowable stress of the materials of the support, etc.

支柱、はり又ははりの支持物(以下この条において「支柱等」という。)が組み合わされた構造のものでないときは、設計荷重(型枠支保工が支える物の重量に相当する荷重に、型枠一平方メートルにつき百五十キログラム以上の荷重を加えた荷重をいう。以下この条において同じ。)により当該支柱等に生ずる応力の値が当該支柱等の材料の許容応力の値を超えないこと。

Article 240, paragraph (3), item (ii)

when the support, etc., has a combined structure, the design load does not exceed the maximum working load designated by the manufacturer of the support, etc.

支柱等が組み合わされた構造のものであるときは、設計荷重が当該支柱等を製造した者の指定する最大使用荷重を超えないこと。

Article 240, paragraph (3), item (iii)

when a steel tubing frame is used as a support, the concrete form shoring is to have a safe structure even when the horizontal weight applied on its top is equivalent to 2.5% of the design load.

鋼管枠を支柱として用いるものであるときは、当該型枠支保工の上端に、設計荷重の百分の二・五に相当する水平方向の荷重が作用しても安全な構造のものとすること。

Article 240, paragraph (3), item (iv)

when something other than a steel tubing frame is used as a support, the concrete form shoring is to have a safe structure even when the horizontal weight applied on its top is equivalent to 5% of the design load.

鋼管枠以外のものを支柱として用いるものであるときは、当該型枠支保工の上端に、設計荷重の百分の五に相当する水平方向の荷重が作用しても安全な構造のものとすること。

Article 241第二百四十一条

Value of Allowable Stress(許容応力の値)
Article 241, paragraph (1)

The value of allowable stress of materials set forth in paragraph (3), item (i) of the preceding Article is to comply with the following requirements:

前条第三項第一号の材料の許容応力の値は、次に定めるところによる。

Article 241, paragraph (1), item (i)

the value of allowable bending stress and allowable compressive stress of steel materials are to be two thirds or less of the value of the yield strength of the steel materials or three quarters of the value of the tensile strength, whichever is smaller;

鋼材の許容曲げ応力及び許容圧縮応力の値は、当該鋼材の降伏強さの値又は引張強さの値の四分の三の値のうちいずれか小さい値の三分の二の値以下とすること。

Article 241, paragraph (1), item (ii)

the value of allowable shearing stress of steel materials is to be 38 % or less of the yield strength of the steel materials or three quarters of the value of the tensile strength, whichever is smaller; and

鋼材の許容せん断応力の値は、当該鋼材の降伏強さの値又は引張強さの値の四分の三の値のうちいずれか小さい値の百分の三十八の値以下とすること。

Article 241, paragraph (1), item (iii)

the value of allowable buckling stress of steel materials is to be equal to or less than the value obtained by the calculation using the following formula:

鋼材の許容座屈応力の値は、次の式により計算を行つて得た値以下とすること。

Article 241, paragraph (1), item (iii), (a)

When l/i ≦ Λ

l/i≦Λの場合

Article 241, paragraph (1), item (iii), (a), (1)

бc = ((1 - 0.4((l/i)/Λ)^2)/ν)F

бc=((1-0.4((l/i)/Λ)2)/ν)F

Article 241, paragraph (1), item (iii), (b)

When l/i > Λ

l/i>Λの場合

Article 241, paragraph (1), item (iii), (b), (1)

бc = (0.29/((l/i)/Λ)^2)F

(In these formulas, l, i, Λ, бc, ν and F represent the following values, respectively. l: Length of the support (where the support is restrained from displacement in the horizontal direction, the maximum length among the lengths between the restraining points) (unit: cm) i: Minimum radius of gyration of area of the support (unit: cm) Λ: Critical slenderness ratio = √(π^2E/0.6F) However, π: Circular constant E: Young's modulus of the steel material (unit: N/cm2) бc: Value of allowable buckling stress (unit: N/cm2) ν: Safety factor = 1.5 + 0.57((l/i)/Λ)^2 F: The smaller of the value of the yield strength of the steel material or three quarters of the value of the tensile strength (unit: N/cm2))

бc=(0.29/((l/i)/Λ)2)F

(これらの式において、l、i、Λ、бc、ν及びFは、それぞれ次の値を表すものとする。 l 支柱の長さ(支柱が水平方向の変位を拘束されているときは、拘束点間の長さのうちの最大の長さ)(単位 センチメートル) i 支柱の最小断面二次半径(単位 センチメートル) Λ 限界細長比=√(π2E/0.6F) ただし、π 円周率 E 当該鋼材のヤング係数(単位 ニュートン毎平方センチメートル) бc 許容座屈応力の値(単位 ニュートン毎平方センチメートル) ν 安全率=1.5+0.57((l/i)/Λ)2 F 当該鋼材の降伏強さの値又は引張強さの値の四分の三の値のうちのいずれか小さい値(単位 ニュートン毎平方センチメートル))
Article 241, paragraph (1), item (iv)

the value of allowable bending stress, allowable compressive stress and allowable shearing stress of timber in the direction of fiber are to be equal to or less than the value listed in the right column of the following Table in accordance with the kind of timber listed in the left column of the same Table.

Type of timberValue of Allowable Stress (Unit: N/cm2)
BendingCompressionShearing
Japanese red pine, Japanese black pine, Japanese larch, hiba, hinoki, Japanese hemlock, Oregon pine, or Port Oxford cedar1,3201,180103
Japanese cedar, fir, silver fir, abies, red cedar or Western hemlock1,03088074
Oak1,9101,320210
Japanese chestnut, Japanese oak, Japanese beech, or keyaki1,4701,030150

木材の繊維方向の許容曲げ応力、許容圧縮応力及び許容せん断応力の値は、次の表の上欄に掲げる木材の種類に応じ、それぞれ同表の下欄に掲げる値以下とすること。

木材の種類許容応力の値(単位 ニュートン毎平方センチメートル)
曲げ圧縮せん断
あかまつ、くろまつ、からまつ、ひば、ひのき、つが、べいまつ又はべいひ一、三二〇一、一八〇一〇三
すぎ、もみ、えぞまつ、とどまつ、べいすぎ又はべいつが一、〇三〇八八〇七四
かし一、九一〇一、三二〇二一〇
くり、なら、ぶな又はけやき一、四七〇一、〇三〇一五〇
Article 241, paragraph (1), item (v)

the value of allowable buckling stress of timber in the direction of fiber is to be equal to or less than the value obtained by calculation using the following formula:

木材の繊維方向の許容座屈応力の値は、次の式により計算を行つて得た値以下とすること。

Article 241, paragraph (1), item (v), (a)

When lk/i ≦100; fk = fc(1 - 0.007(lk/i))

lk/i≦100の場合 fk=fc(1-0.007(lk/i))

Article 241, paragraph (1), item (v), (b)

When lk/i > 100: fk = 0.3fc/(lk/100i)^2

(In these formulas, lk, i, fc and fk represent the following values, respectively. lk: Length of the support (where the support is restrained from displacement in the horizontal direction, the maximum length among the lengths between the restraining points) (unit: cm) i: Minimum radius of gyration of area of the support (unit: cm) fc: Value of allowable compressive stress (unit: N/cm2) fk: Value of allowable buckling stress (unit: N/cm2))

lk/i>100の場合 fk=0.3fc/(lk/100i)2

(これらの式において、lk、i、fc及びfkは、それぞれ次の値を表すものとする。 lk 支柱の長さ(支柱が水平方向の変位を拘束されているときは、拘束点間の長さのうち最大の長さ)(単位 センチメートル) i 支柱の最小断面二次半径(単位 センチメートル) fc 許容圧縮応力の値(単位 ニュートン毎平方センチメートル) fk 許容座屈応力の値(単位 ニュートン毎平方センチメートル))
© 2026 japanlaw.orgA copy for reading and reference — not an official source, and not legal advice. Only the Japanese text published by the government has legal effect.Run by Genjido LLC (源氏道合同会社) · contact@genjido.comContactSourcesTermsPrivacy