Chapter VI Prevention of Dangers in Excavating Work (Articles 389-2-2 to 394)
The law as Ministerial Order Partially Amending the Ordinance on Industrial Safety and Health (Ministry of Health, Labour and Welfare Order No. 12 of 2025) leaves it, with the words it changes marked.
The main text is read a page at a time: a chapter to a page, and a long chapter in runs of articles. The whole main text, and the supplementary provisions and appended tables this amendment changes. Those it leaves untouched are on the page for the text in force.
Article 389-2-2第三百八十九条の二の二
Measures to Remove Gas(ガス抜き等の措置)
Article 389-2-2, paragraph (1)
In carrying out the excavating work of tunnels, etc., when flammable gas is liable to be generated, the employer must take measures to remove the gas by boring and other necessary measures to prevent the flammable gas from flowing out in order to prevent explosion or fire due to the flammable gas.
Measures to Prevent Fire in Carrying Out Work of Gas Welding(ガス溶接等の作業を行う場合の火災防止措置)
Article 389-3, paragraph (1)
In carrying out the construction work of tunnels, etc., when the work of welding, cutting or heating metals using the flammable gas and oxygen is carried out inside the tunnels, etc., the employer must take the following measures to prevent fire:
to remove rags, wood chips, paper scraps or other flammable objects lying around inside, cover them with nonflammable objects, or install partitions to prevent sparks arising from the work;
to have the supervisor set forth in Article 257 carry out the following matters in addition to matters set forth in each item of the same Article:
第二百五十七条の指揮者に、同条各号の事項のほか、次の事項を行わせること。
Article 389-3, paragraph (1), item (ii), (a)
to inform to the workers engaging in the work the location of fire extinguishing equipment and the method of using the equipment;
作業に従事する労働者に対し、消火設備の設置場所及びその使用方法を周知させること。
Article 389-3, paragraph (1), item (ii), (b)
to monitor the work process and immediately take necessary measure when having found any abnormality; and
作業の状況を監視し、異常を認めたときは、直ちに必要な措置をとること。
Article 389-3, paragraph (1), item (ii), (c)
to confirm that there is no risk of fire due to sparks, etc., after the work is completed.
作業終了後火花等による火災が生ずるおそれのないことを確認すること。
Article 389-4第三百八十九条の四
Person in Charge of Fire Prevention(防火担当者)
Article 389-4, paragraph (1)
In carrying out the construction work of tunnels, etc., as regards the places inside the tunnel, etc., where fire or arc is used (excluding places where the work set forth in the preceding Article is carried out), the employer must designate a person in charge of fire prevention and have the person carry out the following matters to prevent fire:
to monitor the status of use of fire or arc and immediately take necessary measures when having found any abnormality; and
火気又はアークの使用の状況を監視し、異常を認めたときは、直ちに必要な措置をとること。
Article 389-4, paragraph (1), item (ii)
to confirm that remaining fire has been properly extinguished.
残火の始末の状況について確認すること。
Article 389-5第三百八十九条の五
Fire Extinguishing Equipment(消火設備)
Article 389-5, paragraph (1)
When carrying out construction work of tunnels, etc., the employer must install fire extinguishing equipment suitable for the nature of fire that is expected to break out at appropriate locations in the places where fire or arc is used inside the tunnels, etc., or where a switch board, transformer or circuit breaker is installed, and inform the workers concerned of the location of the fire extinguishing equipment and the method of using the equipment.
The provisions of the preceding three Articles apply mutatis mutandis to the construction work of vertical shafts.
前三条の規定は、たて坑の建設の作業について準用する。
Subsection 1-4 Evacuations第一款の四 退避等
Article 389-7第三百八十九条の七
Evacuation(退避)
Article 389-7, paragraph (1)
In carrying out the construction work of tunnels, etc., when there is imminent danger of an industrial accident occurring by cave-in, inundation, etc., the employer must immediately suspend the work and evacuate the persons engaged in work to a safe place.
In carrying out the construction work of tunnels, etc., when having found that the concentration of the combustible gas inside the tunnel, etc., has reached 30% or more of the lower explosion limit, the employer must immediately evacuate the persons engaged in work to a safe place, discontinue the use of fire or other objects likely to become a source of ignition, and take measures for airing, ventilation, etc.
In the case referred to in the preceding paragraph, until it is confirmed that the concentration of the combustible gas inside the tunnel, etc., is less than 30% of the lower explosion limit, the employer must prohibit persons other than persons engaged in work concerned from entering the inside of the tunnel, etc., by displaying at a readily visible place that such entry is prohibited or by other methods, and when having prohibited it by a method other than display, must display at a readily visible place a notice to the effect that the inside of the tunnel, etc., is subject to prohibition of entry.
When carrying out the construction work of tunnels, etc., the employer must install the devices, etc. listed in the following items in accordance with the classification listed in each item, in order to promptly give warning to the persons engaged in work concerned in the case of cave-in, inundation, gas explosion, fire or other emergencies, and inform the persons engaged in work concerned of the places where the devices, etc. are installed:
when the distance from the entrance of the tunnels, etc., to the working face (hereinafter referred to as "distance to the working face" in this Subsection) has reached 100 m (excluding the case listed in the following item):warning devices such as sirens and emergency bells (hereinafter referred to as "warning devices" in this Article); and
when the distance to the working face has reached 500 m:warning devices, and communication equipment such as telephones, etc. (limited to those enabling communication between the inside and the outside of the tunnel, etc.; hereinafter referred to as "communication equipment" in this Article).
The employer must maintain the proper functioning of the warning devices and communication equipment set forth in the preceding paragraph at all times.
The employer must install a reserve power source, which can be used immediately when an abnormality arises in the power source for the warning devices and communication equipment set forth in paragraph (1).
When carrying out the construction work of tunnels, etc., the employer must provide the apparatuses for evacuation listed in the following items in accordance with the classification listed in each item at appropriate locations, in order to evacuate persons engaged in work in the case of cave-in, inundation, gas explosion, fire or other emergencies, and inform the persons engaged in work concerned of the locations of the apparatuses and the method of using the apparatuses:
for the tunnels, etc., other than those where flammable gas exists and where there is a risk of explosion or fire (excluding the case listed in item (iii)), and when the distance to the working face has reached 100 m:portable lighting apparatuses such as flashlights (hereinafter called "portable illumination apparatuses" in this Article) and other apparatuses necessary for evacuation;
for the tunnels, etc., where flammable gas exists and where there is a risk of explosion or fire (excluding the case listed in the following item), and when the distance to the working face has reached 100 m:respirators such as survival equipment against carbon monoxide (hereinafter referred to as "respirators" in this Article), portable illumination apparatuses and other apparatuses necessary for evacuation; and
when the distance to the working face has reached 500 m:respirators, portable illumination apparatuses and other apparatuses necessary for evacuation.
切羽までの距離が五百メートルに達したとき 呼吸用保護具、携帯用照明器具その他避難に必要な器具
Article 389-10, paragraph (2)
As regards the respirators set forth in the preceding paragraph, the employer must provide the number of respirators equal to or more than the number of persons engaged in work working at the same time (excluding persons engaged in work in the vicinity of the entrance; the same applies in the following paragraph), and maintain their functioning and cleanliness at all times.
As regards the portable illumination apparatuses set forth in paragraph (1), the employer must provide the number of apparatuses equal to or more than the number of persons engaged in work working at the same time, and maintain them to effectively function at all times; provided, however, that this does not apply in the case referred to in item (i) of the same paragraph, when measures to secure illumination necessary for the evacuation of persons engaged in work working at the same time as a group have been taken.
When carrying out the construction work of a tunnel, etc., where the distance to the working face is 100 m or more (500 m for a tunnel, etc., other than one in which combustible gas exists and where there is a risk of explosion or fire), the employer must conduct evacuation and fire drills (hereinafter referred to as "evacuation and other drills") for the persons engaged in work concerned once during the period before the distance to the working face of the tunnel, etc., reaches 100 m and once every period not exceeding six months thereafter in order to prepare for cave-in, inundation, gas explosion, fire, etc.
When having conducted the evacuation drill, etc., the employer must record the following matters and preserve the record for three years:
事業者は、避難等の訓練を行つたときは、次の事項を記録し、これを三年間保存しなければならない。
Article 389-11, paragraph (2), item (i)
the date the drill was conducted;
実施年月日
Article 389-11, paragraph (2), item (ii)
the name of the persons who have undergone the drill; and
訓練を受けた者の氏名
Article 389-11, paragraph (2), item (iii)
the details of the drill.
訓練の内容
Subsection 2 Tunnel Shoring第二款 ずい道支保工
Article 390第三百九十条
Materials(材料)
Article 390, paragraph (1)
The employer must not use materials having marked damage, deformation or corrosions as materials for tunnel shoring.
事業者は、ずい道支保工の材料については、著しい損傷、変形又は腐食があるものを使用してはならない。
Article 390, paragraph (2)
As regards the wooden materials for tunnel shoring, the employer must not use the materials unless they are materials of Japanese red pine or black pine, and other wood that have toughness and are free from the marked defects for strength such as cracks, worm-eaten spots, gnarls and slanted fibers.
The employer must make the structure of tunnel shoring solid in accordance with the condition of nature of the soil, strata, water content, spring water, cracks and loose stones pertaining to the natural ground where the tunnel shoring is to be installed and the method of excavation.
When assembling the tunnel shoring, the employer must prepare in advance a standard drawing, and assemble the shoring according to the standard drawing.
The standard drawing prescribed in the preceding paragraph must indicate the layout, size and materials of the components of the tunnel shoring.
前項の標準図は、ずい道支保工の部材の配置、寸法及び材質が示されているものでなければならない。
Article 393第三百九十三条
Assembly or Alteration(組立て又は変更)
Article 393, paragraph (1)
When assembling or altering the tunnel shoring, the employer must comply with the requirements set forth in the following items:
事業者は、ずい道支保工を組み立て、又は変更するときは、次に定めるところによらなければならない。
Article 393, paragraph (1), item (i)
to lay out a set of components composing the main component on the same plane; and
主材を構成する一組の部材は、同一平面内に配置すること。
Article 393, paragraph (1), item (ii)
for wooden tunnel shoring, to make the degree of compression of each component of the tunnel shoring the same level.
木製のずい道支保工にあつては、当該ずい道支保工の各部材の緊圧の度合が均等になるようにすること。
Article 394第三百九十四条
Prevention of Dangers of Tunnel Shoring(ずい道支保工の危険の防止)
Article 394, paragraph (1)
As regards tunnel shoring, the employer must comply with the requirements set forth in the following items:
事業者は、ずい道支保工については、次に定めるところによらなければならない。
Article 394, paragraph (1), item (i)
to take measures such as providing sill plates to the leg part to prevent the part from subsiding;
脚部には、その沈下を防止するため、皿板を用いる等の措置を講ずること。
Article 394, paragraph (1), item (ii)
for steel arch shoring, to comply with the following requirements:
鋼アーチ支保工にあつては、次に定めるところによること。
Article 394, paragraph (1), item (ii), (a)
to make the support spacing 1.5 m or less;
建込み間隔は、一・五メートル以下とすること。
Article 394, paragraph (1), item (ii), (b)
to take measures such as driving wedges so that the main components create sufficient arch action;
主材がアーチ作用を十分に行なうようにするため、くさびを打ち込む等の措置を講ずること。
Article 394, paragraph (1), item (ii), (c)
to firmly join main components with each other using connecting bolts and connecting girders, bracings, etc.;
つなぎボルト及びつなぎばり、筋かい等を用いて主材相互を強固に連結すること。
Article 394, paragraph (1), item (ii), (d)
to provide slant props at the entrance of tunnels, etc.;
ずい道等の出入口の部分には、やらずを設けること。
Article 394, paragraph (1), item (ii), (e)
when there is a risk of steel arch shoring falling or becoming twisted due to the longitudinal load of tunnels, etc., being applied to the shoring, when longitudinal length of tunnels, etc., supported by steel arch shoring is short, to take measures to prevent the steel arch shoring from falling or becoming twisted, such as providing slant props to parts other than the parts of the entrance of the tunnels, etc.;
when there is a risk of endangering workers due to falling of rocks, to provide sheet piles, wooden sheets, liner plates, etc.;
肌落ちにより労働者に危険を及ぼすおそれのあるときは、矢板、矢木、ライナープレート等を設けること。
Article 394, paragraph (1), item (iii)
for wooden prop type shoring, to comply with following requirements:
木製支柱式支保工にあつては、次に定めるところによること。
Article 394, paragraph (1), item (iii), (a)
to fasten sleepers to the ground with nose girders, etc., to prevent displacement;
大引きは、変位を防止するため、鼻ばり等により地山に固定すること。
Article 394, paragraph (1), item (iii), (b)
to provide slant props at both ends;
両端にはやらずを設けること。
Article 394, paragraph (1), item (iii), (c)
when there is a risk of wooden prop type shoring falling or becoming twisted due to the longitudinal load of tunnels, etc., being applied to the shoring, to take measures to prevent wooden prop type shoring from falling or becoming twisted, such as providing slant props to parts other than both ends;
The day a law or an amendment starts to apply. It is often months or years after promulgation, so that people have time to prepare. The Ministry of Justice's English usually says a law "comes into force" or "comes into effect", and sometimes calls the day its "enforcement date". Its "enforcement" more often means the word's other sense, carrying a law out, as in an Order for Enforcement (施行令), the Cabinet Order (政令) that sets out the details for carrying out an Act.
The Ministry of Justice's English of this passage has a slip, so the English shown is this site's correction of it. The Ministry printed:
when the distance to the working face has reached 500 m:communication equipment such as warning devices, and telephones, etc. (limited to those enabling communication between the inside and the outside of the tunnel, etc.; hereinafter referred to as "communication equipment" in this Article).
Japanese Law Translation, Ministry of Justice
Translates the law as amended by Order of the Ministry of Health, Labour and Welfare No. 185 of 2006 (平成十八年厚生労働省令第百八十五号)
The Ministry of Justice's English of this passage has a slip, so the English shown is this site's correction of it. The Ministry printed:
for the tunnels, etc., where flammable gas exists and where there is a risk of explosion or fire (excluding the case listed in the following item), and when the distance to the working face has reached 100 m:respiration apparatuses such as survival equipment against carbon monoxide (hereinafter referred to as "respiration apparatuses" in this Article), portable illumination apparatuses and other apparatuses necessary for evacuation; and
Japanese Law Translation, Ministry of Justice
Translates the law as amended by Order of the Ministry of Health, Labour and Welfare No. 185 of 2006 (平成十八年厚生労働省令第百八十五号)
The Ministry of Justice's English of this passage has a slip, so the English shown is this site's correction of it. The Ministry printed:
when the distance to the working face has reached 500 m:respiratory protective equipment, portable illumination apparatuses and other apparatuses necessary for evacuation.
Japanese Law Translation, Ministry of Justice
Translates the law as amended by Order of the Ministry of Health, Labour and Welfare No. 185 of 2006 (平成十八年厚生労働省令第百八十五号)
Machine translation, corrected on review, not official
English translation
Written for this site with AI
Corrected by this site
The Ministry of Justice's English of this passage has a slip, so the English shown is this site's correction of it. The Ministry printed:
when there is a risk of wooden prop type shoring falling or becoming twisted due to the longitudinal load of tunnels, etc., being applied to the shoring, to take measures to prevent wooden prop typed shoring from falling or becoming twisted, such as providing slant props to parts other than both ends;
Japanese Law Translation, Ministry of Justice
Translates the law as amended by Order of the Ministry of Health, Labour and Welfare No. 185 of 2006 (平成十八年厚生労働省令第百八十五号)