Ordinance on Industrial Safety and HealthAppended Table 7
Type of Machinery or Other Such Equipment Matters Drawings, etc.
(i) power presses (limited to mechanical presses with an eccentric mechanism such as a crankshaft, and hydraulic presses) (i) type
(ii) pressure capability
(iii) length of stroke
(iv) stopping performance
(v) type of changeover switch
(vi) for a mechanical press with an eccentric mechanism such as a crankshaft:
(a) model of the clutch
(b) model of the brake
(c) number of strokes per minute
(d) die height
(e) amount of slide adjustment
(f) setting position of the overrun monitoring device
(g) number of clutch engagement points
(vii) for a hydraulic press:
(a) maximum descending speed of the slide
(b) inertial descending value
(viii) outline of use:
(a) use
(b) stroke
(c) processing
(ix) outline of safety measures
(x) for one with a mechanism for preventing danger due to the slide, its performance (i) structural drawing or catalog of the power press
(ii) for a power press that has passed the type examination, a copy of the sticker certifying passage of the type examination
(iii) for a power press to which a safety device is to be attached, a copy of the sticker certifying passage of the type examination pertaining to that safety device, and a structural drawing or catalog of that safety device
(iv) for a power press other than those listed in the preceding two items, a drawing or catalog showing the outline of safety measures
(ii) melting furnaces for metals and other minerals (limited to those with a capacity of 1 ton or more) (i) type, model, name of manufacturer, and year and month of manufacture
(ii) type and properties of the metals and other minerals handled
(iii) method of heating
(iv) standard amount of charge, temperature, pressure, and other use conditions
(v) structure, material, and main dimensions
(vi) structure, material, and main dimensions of the cooling equipment, oxygen blowing equipment, pits, and other main attached facilities (i) structural drawing of the melting furnace and its main attached facilities
(ii) drawing showing the outline of the surrounding area of the installation place
(iii) chemical facilities (excluding piping) (excluding those for which the amount of dangerous goods manufactured or handled, or of substances with a flash point of 65°C or higher manufactured or handled, is below the standards specified by the Minister of Health, Labour and Welfare) (i) type, model, and functions
(ii) names and properties of the dangerous goods manufactured or handled, or of the substances with a flash point of 65°C or higher manufactured or handled
(iii) standard amount of charge, temperature, pressure, and other use conditions
(iv) structure, material, and main dimensions
(v) structure, material, and main dimensions of the main attached facilities and piping Arrangement plan and structural drawings of the chemical facilities, the main attached facilities, and piping
(iv) drying equipment (limited to the drying equipment set forth in Article 6, item (viii), (a) or (b) of the Order) (i) type, model, capability, name of manufacturer, and year and month of manufacture
(ii) type and properties of the substances to be dried
(iii) method of heating
(iv) temperature, pressure, and other use conditions
(v) structure, material, and main dimensions
(vi) functions, structure, material, and main dimensions of the ventilation system, temperature measuring apparatus, temperature adjusting apparatus, and other main attached facilities (i) structural drawing
(ii) drawing showing the outline of the surrounding area of the installation place
(v) acetylene welding equipment (excluding mobile types) (i) structure, material, and main dimensions of the floor area, walls, roof, ceiling, entrance and exit doors, and exhaust pipe of the generator room, and the number of devices housed
(ii) type, model, name of manufacturer, and year and month of manufacture of the generator
(iii) type, model, name of manufacturer, year and month of manufacture, number, structure, material, and main dimensions of the safety equipment
(iv) name, structure, material, and main dimensions of the purifier and other attached appliances
(v) structure and capacity of the sludge pit of carbide (i) arrangement plan
(ii) structural drawings of the generator and safety equipment
(iii) structural drawing of the generator room
(iv) drawing showing the outline of the surrounding area of the installation place
(vi) gas welding equipment using manifolds (excluding mobile types) (i) structure and main dimensions of the gas manifold room, and name of the gas stored and the maximum gas storage amount
(ii) structure and main dimensions of the gas manifolds
(iii) type, model, name of manufacturer, year and month of manufacture, number, structure, material, and main dimensions of the safety equipment
(iv) name, structure, material, and main dimensions of the piping, valves, and other attached appliances (i) arrangement plan
(ii) structural drawing of the safety equipment
(iii) structural drawing of the gas manifold room
(iv) drawing showing the outline of the surrounding area of the installation place
(vii) skyline logging cable cranes (limited to those whose prime mover has a rated power output exceeding 7.5 kW) (i) rope reeving system
(ii) maximum working load
(iii) slope distance, inclined angle, and central dangling ratio of effective spans
(iv) structure and diameters of the main cable and work ropes
(v) safety coefficient of the main cable and work ropes (a strength calculation document is to be attached)
(vi) type, rated power output, and maximum traction force of the yarder
(vii) period of installation Arrangement plan
(viii) timber cableways (limited to those with a total slope distance of effective spans of 350 m or more) (i) type
(ii) maximum working load and clearance between carriers
(iii) total slope distance of effective spans
(iv) slope distance, inclined angle, and central dangling ratio of the longest effective span
(v) structure and diameters of the main cable and towing rope
(vi) safety coefficient of the main cable and towing rope (a strength calculation document is to be attached)
(vii) for those that are power driven, type and rated power output of the timber hauling machine
(viii) period of installation Arrangement plan
(ix) railway equipment (i) purpose of use
(ii) positions of the starting point and ending point, and the difference in altitude between them (average gradient)
(iii) length of the track
(iv) minimum radius of curvature and steepest gradient
(v) gauge of the track, distinction between single and double track, and weight of the rails
(vi) length, width, and structure of bridges or landing piers
(vii) type, number, model, weight, traction force, and main dimensions of power cars
(viii) model, capability, and main dimensions of the winch
(ix) type and function of the brakes
(x) conditions of signaling, warning, and lighting equipment
(xi) maximum operating speed
(xii) installation place and structure of the device for preventing breaking into a run
(xiii) for those installed underground, relationship between the railway equipment and its surroundings If the matters listed in the middle column cannot be clearly indicated in writing, drawings such as a plan view, cross-sectional view, and structural drawing pertaining to those matters
(x) concrete form shoring (limited to those with support posts of a height of 3.5 m or more) (i) outline of the concrete structure to be placed
(ii) structure, material, and main dimensions
(iii) period of installation Assembly drawing and arrangement plan
(xi) temporary passages (limited to those whose height and length are each 10 m or more) (i) installation place
(ii) structure, material, and main dimensions
(iii) period of installation Plan view, side view, and cross-sectional view
(xii) scaffoldings (limited to those with a structure of a height of 10 m or more for scaffoldings other than hanging scaffoldings and cantilever scaffoldings) (i) installation place
(ii) type and purpose of use
(iii) structure, material, and main dimensions Assembly drawing and arrangement plan
(xiii) facilities to keep airtight the emission sources of organic solvent vapor, local exhaust ventilation, push-pull type ventilation systems, or general ventilation systems set forth in Article 5 or Article 6 of the Organic Solvent Ordinance (including the case where these provisions apply mutatis mutandis pursuant to Article 38-8 of the Specified Chemical Substances Ordinance) (excluding mobile types) (i) outline of the organic solvent work (meaning the organic solvent work listed in Article 1, paragraph (1), item (vi) of the Organic Solvent Ordinance; hereinafter the same applies in this item)
(ii) outline of the machines or facilities that are emission sources of organic solvent vapor (meaning the organic solvents listed in Appended Table 6-2 of the Order; hereinafter the same applies in this item)
(iii) method of controlling emissions of organic solvent vapor
(iv) for facilities to keep the emission source of organic solvent vapor airtight, the method of keeping it airtight and an outline of the structure of the main parts of the facilities
(v) for a general ventilation system, the model, an outline of the structure of the main parts of the system, and its function (i) drawing of facilities, etc.
(ii) drawing of the workplace where organic solvent work is carried out
(iii) for local exhaust ventilation, a local exhaust ventilation specification document (Form No. 25)
(iv) for a push-pull type ventilation system, a push-pull type ventilation system specification document (Form No. 26)
(xiv) facilities to keep airtight the emission sources of dust of lead, etc. or sintered ore, etc., local exhaust ventilation, or push-pull type ventilation systems prescribed in Article 2, Articles 5 through 15, and Articles 17 through 20 of the Lead Poisoning Ordinance (i) outline of the lead work (meaning the lead work listed in Article 1, item (v) of the Lead Poisoning Ordinance; hereinafter the same applies in this item)
(ii) outline of the machines or facilities that are emission sources of dust of lead, etc. (meaning the lead, etc. listed in Article 1, item (i) of the Lead Poisoning Ordinance; hereinafter the same applies in this item) or sintered ore, etc. (meaning the sintered ore, etc. listed in item (ii) of the same Article; hereinafter the same applies in this item)
(iii) method of controlling emissions of dust of lead, etc. or sintered ore, etc.
(iv) for facilities to keep the emission source of dust of lead, etc. or sintered ore, etc. airtight, the method of keeping it airtight and an outline of the structure of the main structural parts of the facilities (i) drawing of facilities, etc.
(ii) drawing of the workplace where lead work is carried out
(iii) for local exhaust ventilation, a local exhaust ventilation specification document (Form No. 25)
(iv) for a push-pull type ventilation system, a push-pull type ventilation system specification document (Form No. 26)
(xv) machines or equipment used for the work listed in Appended Table 5, item (ii) of the Order (hereinafter referred to as "work" in this item) (i) outline of the work
(ii) outline of the machines or facilities that are emission sources of tetraalkyl lead vapor (meaning the tetraalkyl lead set forth in Appended Table 5, item (i) of the Order; hereinafter the same applies in this item)
(iii) amount of gasoline mixed with tetraalkyl lead that is handled
(iv) model of the machines or equipment used in the work, and an outline of the structure of their main parts and their functions
(v) provision of protective equipment, disinfectants, etc.
(vi) outline of body washing facilities (i) drawing of the machines or equipment used in the work
(ii) drawing of the workplace where the work is carried out
(xvi) facilities to manufacture class 1 substances listed in Article 2, paragraph (1), item (i) of the Specified Chemical Substances Ordinance (hereinafter referred to as "class 1 substances" in this item) or specified class 2 substances, etc. under Article 4, paragraph (1) of the Specified Chemical Substances Ordinance (hereinafter referred to as "specified class 2 substances, etc." in this item) (i) outline of the work of manufacturing class 1 substances or specified class 2 substances, etc.
(ii) outline of the structure of the main structural parts
(iii) method of keeping airtight and an outline of the measures to prevent health impairment when having workers handle those substances (i) drawing showing the surrounding situation and the relationship with the surrounding areas
(ii) structure of the building where the facilities that manufacture class 1 substances or specified class 2 substances, etc. are installed
(iii) drawing showing the layout of the facilities that manufacture class 1 substances or specified class 2 substances, etc.
(iv) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25)
(v) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26)
(xvii) specified chemical facilities set forth in Article 15, paragraph (1), item (x) of the Order (hereinafter referred to as "specified chemical facilities" in this item) and their attached facilities (i) outline of the work of manufacturing or handling specified class 2 substances (meaning the specified class 2 substances listed in Article 2, paragraph (1), item (iii) of the Specified Chemical Substances Ordinance; hereinafter the same applies in this item and the following item) or class 3 substances (meaning the substances listed in Appended Table 3, item (iii) of the Order)
(ii) outline of the structure of the main structural parts
(iii) outline of the structure of the attached facilities (i) drawing showing the surrounding situation and the relationship with the surrounding areas
(ii) structure of the building where the specified chemical facilities are installed
(iii) drawing showing the layout of the specified chemical facilities and their attached facilities
(iv) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25)
(v) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26)
(xviii) emission control facilities installed in an indoor workplace where gas, vapor, or dust of specified class 2 substances or controlled class 2 substances listed in Article 2, paragraph (1), item (v) of the Specified Chemical Substances Ordinance (hereinafter referred to as "controlled class 2 substances" in this item) is released (excluding those pertaining solely to the work listed in Article 2-2, item (ii) or items (iv) through (viii) of the Specified Chemical Substances Ordinance) (i) outline of the work of manufacturing or handling specified class 2 substances or controlled class 2 substances
(ii) for facilities to keep the emission source of gas, vapor, or dust of specified class 2 substances or controlled class 2 substances airtight, the method of keeping it airtight, an outline of the structure of the main structural parts, and their functions
(iii) for a general ventilation system, the model, an outline of the structure of the main structural parts, and its function (i) drawing showing the surrounding situation and the relationship with the surrounding areas
(ii) drawing showing the whole workplace
(iii) drawing of the facilities to keep the emission source of gas, vapor, or dust of specified class 2 substances or controlled class 2 substances airtight, or of the general ventilation system
(iv) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25)
(v) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26)
(xix) exhaust gas treatment devices set forth in Article 10, paragraph (1) of the Specified Chemical Substances Ordinance that pertain to acrolein (i) outline of the work of manufacturing or handling acrolein
(ii) treatment method and treatment capability for exhaust gas
(iii) outline of the structure of the main structural parts (i) drawing showing the surrounding situation and the relationship with the surrounding areas
(ii) drawing of the structure of the exhaust gas treatment devices
(iii) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25)
(iv) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26)
(xx) waste liquid treatment devices set forth in Article 11, paragraph (1) of the Specified Chemical Substances Ordinance (i) outline of the work of waste liquid treatment
(ii) treatment method and treatment capability for waste liquid
(iii) outline of the structure of the main structural parts (i) drawing showing the surrounding situation and the relationship with the surrounding areas
(ii) drawing of the structure of the waste liquid treatment devices
(iii) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25)
(iv) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26)
(xx)-2 emission control facilities pertaining to the 1,3-butadiene, etc. set forth in Article 38-17, paragraph (1) of the Specified Chemical Substances Ordinance (hereinafter referred to as "1,3-butadiene, etc." in this item) (excluding those installed outdoors) (i) outline of the work of taking samples from facilities that manufacture or handle 1,3-butadiene, etc., or of carrying out maintenance and inspection of those facilities
(ii) for facilities to keep the emission source of gas of 1,3-butadiene, etc. airtight, the method of keeping it airtight, an outline of the structure of the main structural parts, and their functions
(iii) for a general ventilation system, the model, an outline of the structure of the main structural parts, and its function (i) drawing showing the surrounding situation and the relationship with the surrounding areas
(ii) drawing showing the whole workplace
(iii) drawing of the facilities to keep the emission source of gas of 1,3-butadiene, etc. airtight, or of the general ventilation system
(iv) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25)
(v) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26)
(xx)-3 emission control facilities pertaining to the diethyl sulfate, etc. set forth in Article 38-18, paragraph (1) of the Specified Chemical Substances Ordinance (hereinafter referred to as "diethyl sulfate, etc." in this item) (excluding those installed outdoors) (i) outline of the work of handling diethyl sulfate, etc. as a catalyst
(ii) for facilities to keep the emission source of vapor of diethyl sulfate, etc. airtight, the method of keeping it airtight, an outline of the structure of the main structural parts, and their functions
(iii) for a general ventilation system, the model, an outline of the structure of the main structural parts, and its function (i) drawing showing the surrounding situation and the relationship with the surrounding areas
(ii) drawing showing the whole workplace
(iii) drawing of the facilities to keep the emission source of vapor of diethyl sulfate, etc. airtight, or of the general ventilation system
(iv) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25)
(v) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26)
(xx)-4 facilities that manufacture or handle the 1,3-propane sultone, etc. set forth in Article 38-19 of the Specified Chemical Substances Ordinance (hereinafter referred to as "1,3-propane sultone, etc." in this item) and their attached facilities (i) outline of the work of manufacturing or handling 1,3-propane sultone, etc.
(ii) outline of the structure of the main structural parts
(iii) outline of the structure of the attached facilities
(iv) method of keeping airtight and an outline of the measures to prevent health impairment when having workers handle that substance (i) drawing showing the surrounding situation and the relationship with the surrounding areas
(ii) structure of the building where the facilities that manufacture or handle 1,3-propane sultone, etc. are installed
(iii) drawing showing the layout of the facilities that manufacture or handle 1,3-propane sultone, etc. and their attached facilities
(iv) drawing of the facilities that manufacture or handle 1,3-propane sultone, etc. and their attached facilities
(xxi) radiation apparatus set forth in Article 15, paragraph (1) of the Ionizing Radiation Ordinance (excluding certified apparatus with indication set forth in Article 12-5, paragraph (2) of the Act on the Regulation of Radioisotopes, etc. (Act No. 167 of 1957) or specified certified apparatus with indication set forth in paragraph (3) of the same Article; hereinafter the same applies in this item) Outline of the work using radiation apparatus, and of products and work processes (i) drawing showing the controlled area
(ii) radiation apparatus specification document (Form No. 27)
(xxii) air conditioning facilities or mechanical ventilation facilities of the centralized management type set forth in Article 5 of the Ordinance on Health Standards in the Office (Order of the Ministry of Labour No. 43 of 1972) (i) air treatment method
(a) air purification method
(b) dehumidifying and moisture-adding method
(c) humidifying method
(d) cooling method
(ii) ventilation capability
(iii) type and capability of the blower or exhauster
(iv) structure of the main structural parts
(v) system for supplying or exhausting air
(vi) procedure for facility inspection If the matters listed in the middle column cannot be clearly indicated in writing, drawings such as a structural drawing and piping arrangement plan pertaining to those matters
(xxiii) machines or facilities having the specified dust emission sources listed in Appended Table 2, items (vi) and (viii) of the Dust Ordinance, and the mold breaking equipment listed in item (xiv) of the same Table (i) outline of the dusty task (meaning the dusty task under Article 2, paragraph (1), item (i) of the Dust Ordinance; hereinafter the same applies)
(ii) type, name, capability, and number of machines or facilities, and the method of preventing dispersal of dust
(iii) when facilities to keep the emission source of dust airtight are used as the method of preventing dispersal of dust, the method of keeping it airtight, an outline of the structure of the main structural parts, and their functions
(iv) when a method other than the method under the preceding item and the method of preventing dispersal of dust by local exhaust ventilation is used, the model of the facilities for preventing dispersal of dust, an outline of the structure of the main structural parts, and their capability (i) drawing showing the surrounding situation and the relationship with the surrounding areas
(ii) drawing showing the layout of the main machines or facilities in the workplace
(iii) drawing showing the structure of the facilities for preventing dispersal of dust other than local exhaust ventilation
(xxiv) local exhaust ventilation or push-pull type ventilation systems installed pursuant to the provisions of Article 4 or the proviso to Article 27, paragraph (1) of the Dust Ordinance Outline of the dusty task (i) drawing showing the surrounding situation and the relationship with the surrounding areas
(ii) drawing showing the layout of the main machines or facilities in the workplace
(iii) for local exhaust ventilation, a local exhaust ventilation specification document (Form No. 25)
(iv) for a push-pull type ventilation system, a push-pull type ventilation system specification document (Form No. 26)
(xxv) emission control facilities installed in an indoor workplace where dust of asbestos, etc. is released (i) outline of the work of handling asbestos, etc. or manufacturing it for testing or research, or of manufacturing samples for asbestos analysis, etc. (meaning the samples for asbestos analysis, etc. prescribed in Article 6, item (xxiii) of the Order)
(ii) for facilities to keep the emission source of dust of asbestos, etc. airtight, the method of keeping it airtight, an outline of the structure of the main structural parts, and their functions
(iii) for a general ventilation system, the model, an outline of the structure of the main structural parts, and its function (i) drawing showing the surrounding situation and the relationship with the surrounding areas
(ii) drawing showing the whole workplace
(iii) drawing of the facilities to keep the emission source of dust of asbestos, etc. airtight, or of the general ventilation system
(iv) when local exhaust ventilation has been installed, a local exhaust ventilation specification document (Form No. 25)
(v) when a push-pull type ventilation system has been installed, a push-pull type ventilation system specification document (Form No. 26)
“Appended Table 5, item (i) of the Order”