# 労働安全衛生規則 / Ordinance on Industrial Safety and Health — 第三百五条 (Article 305)

This is the Markdown twin of https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305. Every law, and how to address a provision: https://japanlaw.org/llms.txt. The same laws as MCP tools (no sign-in): https://japanlaw.org/mcp.

- Law: 労働安全衛生規則 (Ordinance on Industrial Safety and Health), 昭和四十七年労働省令第三十二号
- English title "Ordinance on Industrial Safety and Health": Ministry of Justice translation
- Kind: MinisterialOrdinance — the distinction between 法律 (Act), 政令 (Cabinet Order), 省令 (Ministerial Order) and 条例 (local ordinance) decides who may issue it and what it may say.
- Provision: 第三百五条 (Article 305)（アセチレン溶接装置の構造規格） — address `art-305`
- Text in force since: 2026-10-01
- URL (the page that opens at this provision): https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305
- e-Gov law ID: 347M50002000032 — never renamed. A permanent link, `/l/{lawId}/{address}` on this site, redirects to the page.
- Every provision below carries its address and its URL on the line under it.
- Japanese text: e-Gov 法令検索, Digital Agency (デジタル庁). English: as marked on each line below.

Only the Japanese as published by the government has legal effect; the text
below is a copy of it. Every English rendering below is a translation and
says which kind: the Ministry of Justice's translation, or this
site's machine translation, whose model and date the Sources list names.
They are never merged and never substituted for one another.

---

### 第三百五条（アセチレン溶接装置の構造規格） — (Standards of Acetylene Welding Equipment)
<sup>caption: Ministry of Justice translation — Japanese Law Translation Database System</sup>
<sup>art-305 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305</sup>

      **第一項**  事業者は、ゲージ圧力（以下この条において「圧力」という。）七キロパスカル以上のアセチレンを発生し、又は使用するアセチレン溶接装置（発生器及び安全器を除く。）については、次に定めるところに適合するものとしなければならない。
      <sup>art-305/par-1 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1</sup>
      As regards acetylene welding equipment (excluding generators and safety equipment) that generate or use acetylene of a gauge pressure (hereinafter referred to as "pressure" in this Article) of 7 kPa or more, the employer must conform to the requirements set forth in the following items:
      <sup>Ministry of Justice translation with a slip corrected by this site — not the Ministry's text; the Ministry printed: "As regards acetylene welding equipment (excluding generators and safety equipment) that generate or use acetylene of a gauge pressure (hereinafter referred to as "pressure" in this Article) of 7 kPa or more, the employer must conform to the requiremenst set forth in the following items:" — https://www.japaneselawtranslation.go.jp/en/laws/view/3878/tb</sup>

        **一**  ガスだめは、次に定めるところによるものであること。
        <sup>art-305/par-1/item-1 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1/item-1</sup>
        the gas holder conforms to the following requirements:
        <sup>Ministry of Justice translation — Japanese Law Translation Database System</sup>

          **イ**  主要部分は、次の表の上欄に掲げる内径に応じ、それぞれ同表の下欄に掲げる厚さ以上の鋼板又は鋼管で造られていること。
内径（単位　センチメートル）	鋼板又は鋼管（単位　ミリメートル）
六十未満	二
六十以上百二十未満	二・五
百二十以上二百未満	三・五
二百以上	五
          <sup>art-305/par-1/item-1/sub-1 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1/item-1/sub-1</sup>
          the main parts to be made of steel plates or steel pipes with a thickness equal to or more than that listed in the right column of the following table in accordance with the inner diameter listed in the left column of the same table;
Inner diameter (unit: cm)	Steel plate or steel pipe (unit: mm)
Less than 60	2
60 or more and less than 120	2.5
120 or more and less than 200	3.5
200 or more	5
          <sup>machine translation, not official</sup>

          **ロ**  主要部分の鋼板又は鋼管の接合方法は、溶接、びよう接又はボルト締めによるものであること。
          <sup>art-305/par-1/item-1/sub-2 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1/item-1/sub-2</sup>
          the method of joining steel plates or steel pipes of the main parts to be welding, or using rivet joints or bolt joints; and
          <sup>Ministry of Justice translation — Japanese Law Translation Database System</sup>

          **ハ**  アセチレンと空気との混合ガスを排出するためのガス逃がし弁又はコツクを備えていること。
          <sup>art-305/par-1/item-1/sub-3 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1/item-1/sub-3</sup>
          to be equipped with a gas escape valve or a cock to discharge a mixed gas of acetylene and air;
          <sup>machine translation, not official</sup>

        **二**  発生器から送り出された後、圧縮装置により圧縮されたアセチレンのためのガスだめにあつては、前号に定めるところによるほか、次に定める安全弁及び圧力計を備えていること。
        <sup>art-305/par-1/item-2 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1/item-2</sup>
        for the gas holder for acetylene that is compressed by a compressor after being fed from the generator, in addition to compliance with the requirements set forth in the preceding item, to be equipped with a safety valve and a pressure gauge as prescribed in the following sub-items:
        <sup>Ministry of Justice translation — Japanese Law Translation Database System</sup>

          **イ**  安全弁
          <sup>art-305/par-1/item-2/sub-1 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1/item-2/sub-1</sup>
          safety valve
          <sup>Ministry of Justice translation — Japanese Law Translation Database System</sup>

            **（イ）**  ガスだめ内の圧力が百四十キロパスカルに達しないうちに作動し、かつ、その圧力が常用圧力から十キロパスカル低下するまでの間に閉止するものであること。
            <sup>art-305/par-1/item-2/sub-1/sub2-1 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1/item-2/sub-1/sub2-1</sup>
            being one that operates before the pressure inside the gas holder reaches 140 kPa and closes by the time the pressure falls by 10 kPa from the normal working pressure;
            <sup>machine translation, not official</sup>

            **（ロ）**  発生器が最大量のアセチレンを発生する場合において、ガスだめ内の圧力を百五十キロパスカル未満に保持する能力を有するものであること。
            <sup>art-305/par-1/item-2/sub-1/sub2-2 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1/item-2/sub-1/sub2-2</sup>
            having the capacity to keep the pressure inside the gas holder at less than 150 kPa when the generator generates the maximum quantity of acetylene;
            <sup>machine translation, not official</sup>

          **ロ**  圧力計
          <sup>art-305/par-1/item-2/sub-2 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1/item-2/sub-2</sup>
          pressure gauge
          <sup>Ministry of Justice translation — Japanese Law Translation Database System</sup>

            **（イ）**  目もり盤の径は、定置式のガスだめに取り付けるものにあつては七十五ミリメートル以上、移動式のガスだめに取り付けるものにあつては五十ミリメートル以上であること。
            <sup>art-305/par-1/item-2/sub-2/sub2-1 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1/item-2/sub-2/sub2-1</sup>
            having a dial with a diameter of 75 mm or more for a gauge attached to a stationary gas holder, and 50 mm or more for a gauge attached to a portable gas holder;
            <sup>machine translation, not official</sup>

            **（ロ）**  目もり盤の最大指度は、常用圧力の一・五倍以上、かつ、五百キロパスカル以下の圧力を示すものであること。
            <sup>art-305/par-1/item-2/sub-2/sub2-2 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1/item-2/sub-2/sub2-2</sup>
            having a dial whose maximum reading indicates a pressure of 1.5 times the normal working pressure or more and 500 kPa or less;
            <sup>machine translation, not official</sup>

            **（ハ）**  目もりには、常用圧力を示す位置に見やすい表示がされているものであること。
            <sup>art-305/par-1/item-2/sub-2/sub2-3 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1/item-2/sub-2/sub2-3</sup>
            having a conspicuous indication on the scale at the position indicating the normal working pressure;
            <sup>machine translation, not official</sup>

        **三**  ガスだめ、清浄器、導管等のアセチレンと接触する部分は、銅又は銅を七十パーセント以上含有する合金を使用しないものであること。
        <sup>art-305/par-1/item-3 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1/item-3</sup>
        for the parts of the gas holder, purifiers, acetylene distributing lines, etc., which contact acetylene, copper or an alloy containing 70% or more copper are not used.
        <sup>Ministry of Justice translation — Japanese Law Translation Database System</sup>

      **第二項**  事業者は、前項のアセチレン溶接装置以外のアセチレン溶接装置の清浄器、導管等でアセチレンが接触するおそれのある部分には、銅を使用してはならない。
      <sup>art-305/par-2 · https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-2</sup>
      The employer must not use copper for the parts of the purifiers, acetylene distributing lines etc., of acetylene welding equipment other than those set forth in the preceding paragraph that is likely to come in contact with acetylene.
      <sup>Ministry of Justice translation — Japanese Law Translation Database System</sup>

---

## Cites
- art-305/par-1: この条 → 労働安全衛生規則 第三百五条 (Article 305), art-305 — https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305
- art-305/par-1/item-2: 前号 → 労働安全衛生規則 第三百五条第一項第一号 (Article 305, paragraph (1), item (i)), art-305/par-1/item-1 — https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1/item-1
- art-305/par-2: 前項 → 労働安全衛生規則 第三百五条第一項 (Article 305, paragraph (1)), art-305/par-1 — https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1

## Cited by

4 provisions cite this one. No official source publishes this direction.

- 労働安全衛生規則 第三百五条第一項（アセチレン溶接装置の構造規格） — https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1
- 労働安全衛生規則 第三百五条第一項第二号（アセチレン溶接装置の構造規格） — https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-1/item-2
- 労働安全衛生規則 第三百五条第二項（アセチレン溶接装置の構造規格） — https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-305/par-2
- 労働安全衛生規則 第六百四十七条第一項第二号（アセチレン溶接装置についての措置） — https://japanlaw.org/ja/industrial-safety-and-health-ordinance/art-647/par-1/item-2

---

## Sources

- claude-opus-5-5 — Corrections to the Ministry of Justice's English of paragraphs, written 2026-11-13
- e-Gov 法令検索, Digital Agency (デジタル庁) — 労働安全衛生規則 — the text in force from 2026-10-01 (https://laws.e-gov.go.jp/law/347M50002000032/20261001_508M60000100116), retrieved 2026-11-13
- Japanese Law Translation Database System, Ministry of Justice (法務省) — Ordinance on Industrial Safety and Health (労働安全衛生規則), Article 305, paragraph (1) — the Ministry of Justice's English as printed (https://www.japaneselawtranslation.go.jp/en/laws/view/3878/tb), retrieved 2026-11-13
- Japanese Law Translation Database System, Ministry of Justice (法務省) — Ordinance on Industrial Safety and Health — Ministry of Justice translation (https://www.japaneselawtranslation.go.jp/en/laws/view/3878/tb), retrieved 2026-11-13
- claude-sonnet-5-5 — Machine translation, batch industrial-safety-and-health-ordinance-20261113T030819-037, translated 2026-11-13
- This site's parser, version 240 — 労働安全衛生規則 — structure, counts, cross-references and defined terms, computed 2026-11-13