# 労働安全衛生規則 / Ordinance on Industrial Safety and Health — 第五百七十五条の二 (Article 575-2)

This is the Markdown twin of https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-575-2. Every law, and how to address a provision: https://japanlaw.org/llms.txt. The same laws as MCP tools (no sign-in): https://japanlaw.org/mcp.

- Law: 労働安全衛生規則 (Ordinance on Industrial Safety and Health), 昭和四十七年労働省令第三十二号
- English title "Ordinance on Industrial Safety and Health": Ministry of Justice translation
- Kind: MinisterialOrdinance — the distinction between 法律 (Act), 政令 (Cabinet Order), 省令 (Ministerial Order) and 条例 (local ordinance) decides who may issue it and what it may say.
- Provision: 第五百七十五条の二 (Article 575-2)（材料等） — address `art-575-2`
- Text in force since: 2026-10-01
- URL (the page that opens at this provision): https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-575-2
- e-Gov law ID: 347M50002000032 — never renamed. A permanent link, `/l/{lawId}/{address}` on this site, redirects to the page.
- Every provision below carries its address and its URL on the line under it.
- Japanese text: e-Gov 法令検索, Digital Agency (デジタル庁). English: as marked on each line below.

Only the Japanese as published by the government has legal effect; the text
below is a copy of it. Every English rendering below is a translation and
says which kind: the Ministry of Justice's translation, or this
site's machine translation, whose model and date the Sources list names.
They are never merged and never substituted for one another.

---

### 第五百七十五条の二（材料等） — (Materials)
<sup>caption: Ministry of Justice translation — Japanese Law Translation Database System</sup>
<sup>art-575-2 · https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-575-2</sup>

  **第一項**  事業者は、仮設の支柱及び作業床等により構成され、材料若しくは仮設機材の集積又は建設機械等の設置若しくは移動を目的とする高さが二メートル以上の設備で、建設工事に使用するもの（以下「作業構台」という。）の材料については、著しい損傷、変形又は腐食のあるものを使用してはならない。
  <sup>art-575-2/par-1 · https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-575-2/par-1</sup>
  As regards materials used for the facilities composed of temporary supports, work platforms, etc., for the purpose of piling up materials or temporary equipment, or of installing or moving construction machines, etc., and having a height of 2 m or more (hereinafter referred to as "working platforms"), the employer must not use those with marked damage, deformation or corrosion.
  <sup>Ministry of Justice translation — Japanese Law Translation Database System</sup>

  **第二項**  事業者は、作業構台に使用する木材については、強度上の著しい欠点となる割れ、虫食い、節、繊維の傾斜等がないものでなければ、使用してはならない。
  <sup>art-575-2/par-2 · https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-575-2/par-2</sup>
  As regards the lumbers for working platforms, the employer must not use them unless they are free from cracks, worm-eaten spots, gnarls, slant fibers that are marked defects in terms of strength.
  <sup>Ministry of Justice translation with a slip corrected by this site — not the Ministry's text; the Ministry printed: "As regards the lumbers for working platforms, the employer must not use then unless they are free from cracks, worm-eaten spots, gnarls, slant fibers that are marked defects in terms of strength." — https://www.japaneselawtranslation.go.jp/en/laws/view/3878/tb</sup>

  **第三項**  事業者は、作業構台に使用する支柱、作業床、はり、大引き等の主要な部分の鋼材については、日本産業規格Ｇ三一〇一（一般構造用圧延鋼材）、日本産業規格Ｇ三一〇六（溶接構造用圧延鋼材）、日本工業規格Ｇ三一九一（熱間圧延棒鋼）、日本工業規格Ｇ三一九二（熱間圧延形鋼）、日本産業規格Ｇ三四四四（一般構造用炭素鋼鋼管）若しくは日本産業規格Ｇ三四六六（一般構造用角形鋼管）に定める規格に適合するもの又はこれと同等以上の引張強さ及びこれに応じた伸びを有するものでなければ、使用してはならない。
  <sup>art-575-2/par-3 · https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-575-2/par-3</sup>
  As regards steel materials for main parts of supports, work floors, girders, sleepers, etc. to be used for working platforms, the employer must not use them unless they conform to the Japanese Industrial Standard G 3101 (Rolled Steel for General Structure), Japanese Industrial Standard G 3106 (Rolled Steel for Welded Structure), Japanese Industrial Standard G 3191 (Hot Rolled Steel Bar), Japanese Industrial Standard G 3192 (Hot Rolled Steel Sections), Japanese Industrial Standard G 3444 (Carbon Steel Tubes for General Structural Purposes) or Japanese Industrial Standard G 3466 (Carbon Steel Square Pipes for General Structural Purposes), or have a tensile strength equal to or greater than that prescribed in those Standards and an elongation corresponding to that tensile strength.
  <sup>machine translation, not official</sup>

## Cited by

1 provision cites this one. No official source publishes this direction.

- 労働安全衛生規則 第六百五十五条の二第一項第三号（作業構台についての措置） — https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-655-2/par-1/item-3

---

## Sources

- claude-opus-5-5 — Corrections to the Ministry of Justice's English of paragraphs, written 2026-11-13
- e-Gov 法令検索, Digital Agency (デジタル庁) — 労働安全衛生規則 — the text in force from 2026-10-01 (https://laws.e-gov.go.jp/law/347M50002000032/20261001_508M60000100116), retrieved 2026-11-13
- Japanese Law Translation Database System, Ministry of Justice (法務省) — Ordinance on Industrial Safety and Health (労働安全衛生規則), Article 575-2, paragraph (2) — the Ministry of Justice's English as printed (https://www.japaneselawtranslation.go.jp/en/laws/view/3878/tb), retrieved 2026-11-13
- Japanese Law Translation Database System, Ministry of Justice (法務省) — Ordinance on Industrial Safety and Health — Ministry of Justice translation (https://www.japaneselawtranslation.go.jp/en/laws/view/3878/tb), retrieved 2026-11-13
- claude-sonnet-5-5, corrected on review by claude-opus-5-5 — Machine translation corrected on review, batch industrial-safety-and-health-ordinance-20261113T030819-046, translated 2026-11-13
- This site's parser, version 240 — 労働安全衛生規則 — structure, counts, cross-references and defined terms, computed 2026-11-13