# 労働安全衛生規則 / Ordinance on Industrial Safety and Health — 第百五十条の三 (Article 150-3)

This is the Markdown twin of https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3. Every law, and how to address a provision: https://japanlaw.org/llms.txt. The same laws as MCP tools (no sign-in): https://japanlaw.org/mcp.

- Law: 労働安全衛生規則 (Ordinance on Industrial Safety and Health), 昭和四十七年労働省令第三十二号
- English title "Ordinance on Industrial Safety and Health": Ministry of Justice translation
- Kind: MinisterialOrdinance — the distinction between 法律 (Act), 政令 (Cabinet Order), 省令 (Ministerial Order) and 条例 (local ordinance) decides who may issue it and what it may say.
- Provision: 第百五十条の三 (Article 150-3)（教示等） — address `art-150-3`
- Text in force since: 2026-10-01
- URL (the page that opens at this provision): https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3
- e-Gov law ID: 347M50002000032 — never renamed. A permanent link, `/l/{lawId}/{address}` on this site, redirects to the page.
- Every provision below carries its address and its URL on the line under it.
- Japanese text: e-Gov 法令検索, Digital Agency (デジタル庁). English: as marked on each line below.

Only the Japanese as published by the government has legal effect; the text
below is a copy of it. Every English rendering below is a translation and
says which kind: the Ministry of Justice's translation, or this
site's machine translation, whose model and date the Sources list names.
They are never merged and never substituted for one another.

---

### 第百五十条の三（教示等） — (Teaching)
<sup>caption: Ministry of Justice translation — Japanese Law Translation Database System</sup>
<sup>art-150-3 · https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3</sup>

    **第一項**  事業者は、産業用ロボットの可動範囲内において当該産業用ロボットについて教示等の作業を行うときは、当該産業用ロボットの不意の作動による危険又は当該産業用ロボットの誤操作による危険を防止するため、次の措置を講じなければならない。ただし、第一号及び第二号の措置については、産業用ロボットの駆動源を遮断して作業を行うときは、この限りでない。
    <sup>art-150-3/par-1 · https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3/par-1</sup>
    When carrying out the work of instruction, etc. for an industrial robot within the movable range of the industrial robot, the employer must take the following measures in order to prevent the dangers due to an unexpected activation or an operational error of the industrial robot; provided, however, that this does not apply to the measures set forth in items (i) and (ii), when work is carried out while the power source of the industrial robot is shut off.
    <sup>machine translation, not official</sup>

      **一**  次の事項について規程を定め、これにより作業を行わせること。
      <sup>art-150-3/par-1/item-1 · https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3/par-1/item-1</sup>
      to establish rules for the following matters and have workers carry out the work according to the rules:
      <sup>Ministry of Justice translation — Japanese Law Translation Database System</sup>

        **イ**  産業用ロボットの操作の方法及び手順
        <sup>art-150-3/par-1/item-1/sub-1 · https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3/par-1/item-1/sub-1</sup>
        the method and the procedure for operating the industrial robot;
        <sup>machine translation, not official</sup>

        **ロ**  作業中のマニプレータの速度
        <sup>art-150-3/par-1/item-1/sub-2 · https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3/par-1/item-1/sub-2</sup>
        the speed of the manipulator in operation;
        <sup>Ministry of Justice translation — Japanese Law Translation Database System</sup>

        **ハ**  複数の労働者に作業を行わせる場合における合図の方法
        <sup>art-150-3/par-1/item-1/sub-3 · https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3/par-1/item-1/sub-3</sup>
        the method of signals when having more than one worker carry out the work;
        <sup>Ministry of Justice translation — Japanese Law Translation Database System</sup>

        **ニ**  異常時における措置
        <sup>art-150-3/par-1/item-1/sub-4 · https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3/par-1/item-1/sub-4</sup>
        the measures in emergencies;
        <sup>Ministry of Justice translation — Japanese Law Translation Database System</sup>

        **ホ**  異常時に産業用ロボットの運転を停止した後、これを再起動させるときの措置
        <sup>art-150-3/par-1/item-1/sub-5 · https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3/par-1/item-1/sub-5</sup>
        the measures for resuming the operation of the industrial robot after suspending its operation in emergencies;
        <sup>machine translation, not official</sup>

        **ヘ**  その他産業用ロボットの不意の作動による危険又は産業用ロボットの誤操作による危険を防止するために必要な措置
        <sup>art-150-3/par-1/item-1/sub-6 · https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3/par-1/item-1/sub-6</sup>
        other necessary measures for preventing dangers due to an unexpected activation or an erroneous operation of the industrial robot;
        <sup>machine translation, not official</sup>

      **二**  作業従事者又は当該者を監視する者が異常時に直ちに産業用ロボットの運転を停止することができるようにするための措置を講ずること。
      <sup>art-150-3/par-1/item-2 · https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3/par-1/item-2</sup>
      to take measures in order to enable a person engaged in work or a person who oversees that person to immediately suspend the operation of the industrial robot in emergencies; and
      <sup>machine translation, not official</sup>

      **三**  作業を行つている間産業用ロボットの起動スイッチ等に作業中である旨を表示する等作業従事者以外の者が当該起動スイッチ等を操作することを防止するための措置を講ずること。
      <sup>art-150-3/par-1/item-3 · https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3/par-1/item-3</sup>
      to take measures such as displaying on the start switch, etc., of the industrial robot that work is in progress while the work is being carried out, in order to prevent persons other than persons engaged in work from operating the start switch, etc.
      <sup>machine translation, not official</sup>

---

## Cites
- art-150-3/par-1: 第一号 → 労働安全衛生規則 第百五十条の三第一項第一号 (Article 150-3, paragraph (1), item (i)), art-150-3/par-1/item-1 — https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3/par-1/item-1
- art-150-3/par-1: 第二号 → 労働安全衛生規則 第百五十条の三第一項第二号 (Article 150-3, paragraph (1), item (ii)), art-150-3/par-1/item-2 — https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3/par-1/item-2

## Cited by

1 provision cites this one. No official source publishes this direction.

- 労働安全衛生規則 第百五十条の三第一項（教示等） — https://japanlaw.org/en/industrial-safety-and-health-ordinance/art-150-3/par-1

---

## Sources

- e-Gov 法令検索, Digital Agency (デジタル庁) — 労働安全衛生規則 — the text in force from 2026-10-01 (https://laws.e-gov.go.jp/law/347M50002000032/20261001_508M60000100116), retrieved 2026-11-13
- Japanese Law Translation Database System, Ministry of Justice (法務省) — Ordinance on Industrial Safety and Health — Ministry of Justice translation (https://www.japaneselawtranslation.go.jp/en/laws/view/3878/tb), retrieved 2026-11-13
- claude-sonnet-5-5 — Machine translation, batch industrial-safety-and-health-ordinance-20261113T030819-021, translated 2026-11-13